Takeshi SHIMOTO

J-GLOBAL         Last updated: Mar 1, 2019 at 09:14
 
Avatar
Name
Takeshi SHIMOTO
Affiliation
Fukuoka Institute of Technology
Section
Faculty of Information Engineering Department of Information and Systems Engineering
Job title
Lecture
Degree
Doctor(Engineering)(Kyushu Sangyo University)

Research Interests

 
 

Research Areas

 
 

Published Papers

 
K. Murakami, S. Hamai, T. Moro-oka, T. Moro-oka, K. Okazaki, H. Higaki, T. Shimoto, S. Ikebe, Y. Nakashima
Revue de Chirurgie Orthopedique et Traumatologique   104 132-183   Apr 2018   [Refereed]
© 2017 Elsevier Masson SAS Background: Rotational allowance at the tibiofemoral joint would be required during deep flexion. However, the amount of flexion and rotation has not been investigated in modern total knee arthroplasty (TKA) designs. The...
宮地頼太, 宮本知佳, 下戸健, 石川篤, 日垣秀彦, 見明豪, 小薗直哉, 岡田貴允
日本機械学会論文集(Web)   84(859) ROMBUNNO.17‐00191(J‐STAGE)   Apr 2018   [Refereed]
Takeshi Shimoto,Xiu-Ying Zhang,Shizuka Akieda,Atsushi Ishikawa,Hidehiko Higaki,Koichi Nakayama
JRM   30(5) 819-826   2018   [Refereed]
反復ランニング時のアジリティ評価と新体力テストとの関係
梅野 貴俊, 下戸 健, 日垣 秀彦
臨床バイオメカニクス   38 367-372   Oct 2017   [Refereed]
著者等は、アジリティに関する運動能力を定量的に評価する装置を作製し、小学生アスリートの評価を行ってきた。今回、本装置を用いて反復ランニング時のアジリティ評価を行い、小学校で実施されている新体力テストの種目である「反復横とび」「立ち幅とび」「短距離走」「往復持久走」との相関関係について検討した。対象は県内のバスケットボールチームに所属する小学生女子22名(8〜12歳)とした。検討の結果、アジリティ評価値は新体力テスト全種目の測定値と有意な相関を示し、著者等が行っているアジリティ評価は新たな運...
Rachanart Soontornvorn, Hiroyuki Fujioka, Takeshi Shimoto
IEEE Region 10 Annual International Conference, Proceedings/TENCON   3720-3723   Feb 2017   [Refereed]
© 2016 IEEE. This paper considers a problem of training human skills in the calligraphy with a long-slip of paper 'TANZAKU'. For such a problem, we here develop a novel training system by using Augmented Reality (AR) technology. Therein, the dynam...
N. Kozono, T. Okada, N. Takeuchi, M. Hanada, M. Hanada, T. Shimoto, Y. Iwamoto
Journal of Hand Surgery: European Volume   41 802-808   Oct 2016   [Refereed]
© The British Society for Surgery of the Hand. Under cyclic loading, we recorded the fatigue strength of a six-strand tendon repair with different symmetry in the lengths of suture purchase in two stumps of 120 dental rolls and in 30 porcine tendo...
王 亦峰, 池部 怜, 石川 篤, 白石 善孝, 下戸 健, 中西 義孝, 濵井 敏, 岡崎 賢, 岩本 幸英, 日垣 秀彦
臨床バイオメカニクス   37 267-273   Oct 2016   [Refereed]
池部 怜, 王 亦峰, 石川 篤, 白石 善孝, 下戸 健, 中西 義孝, 原 大介, 濵井 敏, 中島 康晴, 岩本 幸英, 日垣 秀彦
臨床バイオメカニクス   37 251-255   Oct 2016   [Refereed]
Takeshi Shimoto, Nozomi Hidaka, Hiromichi Sasaki, Koichi Nakayama, Shizuka Akieda, Shuichi Matsuda, Hiromasa Miura, Yukihide Iwamoto
Lecture Notes in Electrical Engineering   253 LNEE 855-862   Aug 2013   [Refereed]
Cells construct is made by spheroid-culturing the cells and collecting the spheroids. The spheroids are manufactured by dispensing cell turbid liquid into a special multiwell plate. If there is a difference in the number of cells when dispensing t...
Takeshi Shimoto,Nozomi Hidaka,Hiromichi Sasaki,Koichi Nakayama,Shizuka Akieda,Shuichi Matsuda,Hiromasa Miura,Yukihide Iwamoto
Information Technology Convergence - Security, Robotics, Automations and Communication, 5th International Conference on Information Technology Convergence and Services, ITCS 2013, Fukuoka, Japan, July 8-10, 2013.   855-862   2013   [Refereed]
白石 善孝, 下戸 健, 日垣 秀彦
臨床バイオメカニクス   33 185-192   Oct 2012   [Refereed]
Takeshi Shimoto, Koichi Nakayama, Shuichi Matsuda, Yukihide Iwamoto
Journal of Robotics and Mechatronics   24 347-353   Jan 2012   [Refereed]
We have been working on the development of scaffold free cell delivery system, and showing good results in the regeneration of rabbit osteochondral defect for more than three years by implantation of molded mesenchymal stem cells construct without...
S. Kawahara, S. Matsuda, S. Fukagawa, H. Mitsuyasu, H. Nakahara, H. Higaki, T. Shimoto, Y. Iwamoto
Journal of Bone and Joint Surgery - Series B   94 B 56-61   Jan 2012   [Refereed]
In posterior stabilised total knee replacement (TKR) a larger femoral component is sometimes selected to manage the increased flexion gap caused by resection of the posterior cruciate ligament. However, concerns remain regarding the adverse effect...
Takeshi Shimoto,Koichi Nakayama,Shuichi Matsuda,Yukihide Iwamoto
JRM   24(2) 347-353   2012   [Refereed]
SHIRAISHI Yoshitaka, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, TASHIRO Yasutaka, MIURA Hiromasa, IWAMOTO Yukihide, HARA Toshiaki
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C   77(782) 3761-3769   Dec 2011   [Refereed]
In biomechanics of the knee joints, the definition of the cruciate ligament adhesion areas is discussed for the cruciate ligament reconstruction. Effective information can be expected to be fed back to the cruciate ligament reconstruction if accur...
N. Takeuchi, H. Mitsuyasu, K. Kikuchi, T. Shimoto, H. Higaki, Y. Iwamoto
Journal of Hand Surgery: European Volume   36 584-589   Sep 2011   [Refereed]
The gap formation of five core plus peripheral suture techniques for flexor tendon repair was evaluated by cyclic load testing. Fifty pairs of dental roll tendon models were sutured using six-strand Pennington modified Kessler core suture with 4-0...
S.Hamai, H.Miura, S.Matsuda, T.Shimoto, H.Higaki, Y.Iwamoto
Journal of Bone and Joint Surgery   92(8) 1765-1773   Jul 2010   [Refereed]
Background: Retrieval studies have demonstrated polyethylene wear and deformation of the anterior aspect of the tibial post of posterior-stabilized total knee replacements. We are not aware of any study that has analyzed the effects of the design ...
S.Hamai, T.Moro-Oka, H.Miura, T.Shimoto, H.Higaki, Fregly BJ, Y.Iwamoto, Banks SA
Journal of Orthopaedic Research   27(12) 1555-1561   Dec 2009   [Refereed]
Dynamic knee kinematics were analyzed for medial osteoarthritic (OA) knees in three activities, including two types of maximum knee flexion. Continuous x-ray images of kneeling, squatting, and stair climbing motions were taken using a large flat p...
HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C   75(755) 2044-2050   Jul 2009   [Refereed]
For the operative method and evaluation of patients, it is important to clarify three-dimensional kinematics of the natural joint. The study aimed to develop a three-dimensional motion analysis for natural knee joints in vivo, using an image match...
S. Hamai, H. Miura, H. Higaki, T. Shimoto, Y. Nakanishi, Y. Iwamoto
J Orthop Sci.   82(12) 543-549   Dec 2008   [Refereed]
Background. The purpose of this study was to investigate the kinematics of the polyethylene insert in two designs of mobilebearing total knee arthroplasty, using a six-degrees-of-freedom knee simulator. It was consequently not clear whether the mo...
S. Hamai, H. Miura, H. Higaki, T. Shimoto, S. Matsuda, K. Okazaki, Y. Iwamoto
J Orthop Res.   26(12) 1556-1561   Dec 2008   [Refereed]
The expectation of returning to sports activities after total knee arthroplasty (TKA) has become more important to patients than ever. To our knowledge, no studies have been published evaluating the three-dimensional knee joint kinematics during s...
S. Hamai, H. Miura, H. Higaki, T. Shimoto, S. Matsuda, K. Okazaki, Y. Iwamoto
J Bone Joint Surg Br.   90(9) 1180-1185   Sep 2008   [Refereed]
Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LP...
Y. Akasaki, S. Matsuda, T. Shimoto, H. Miura, H. Higaki, Y. Iwamoto
J Arthroplasty.   23(5) 736-743   Aug 2008   [Refereed]
The present study evaluated the effects of extent of conformity of post-cam design on contact area and stress at post-cam mechanism using 4 different posterior-stabilized prostheses. TRAC and Alpina with full-conformed post-cams exhibited the larg...
S. Hamai, H. Miura, H. Higaki, S. Matsuda, T. Shimoto, K. Sasaki, M. Yoshizumi, K. Okazaki, N. Tsukamoto, Y. Iwamoto
J Orthop Res.   26(4) 435-442   Apr 2008   [Refereed]
Kneeling is an important function of the knee for many activities of daily living. In this study, we evaluated the in vivo kinematics of kneeling after total knee arthroplasty (TKA) using radiographic based image-matching techniques. Kneeling from...
T. Moro-oka, S. Hamai, H. Miura, T. Shimoto, H. Higaki, BJ. Fregly, Y. Iwamoto, SA. Banks
J Orthop Res.   26(4) 428-434   Apr 2008   [Refereed]
Dynamic knee kinematics were analyzed for normal knees in three activities, including two different types of maximum knee flexion. Continuous X-ray images of kneel, squat, and stair climb motions were taken using a large flat panel detector. CT-de...
T.Moro-oka, S.Hamai, H.Miura, T.Shimoto, H.Higaki, Benjamin J. Fregly, Y.Iwamoto
J Orthop Res.   25 867-872   Jul 2007   [Refereed]
The purpose of this study was to compare three-dimensional (3D) kinematic measurements from single-plane radiographic projections using bone models created from magnetic resonance imaging (MRI) and computed tomography (CT). MRI is attractive becau...
SHIMOTO Takeshi, HIGAKI Hidehiko, YASUTAKE Seiji, YOSHIZUMI Masa-aki, NAKANISHI Yoshitaka, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
Biomechanism   18 71-78   Sep 2006   [Refereed]
Analysis of the three-dimensional (3-D) kinematics in vivo is expected to be one of the most important techniques for post-operative evaluations of total knee arthroplasty (TKA) design. The aim of this study was to analyze motion of an implanted k...
Motion analysis of kneeling in cruciate-retaining and posterior-substituting total knee arthroplasty
H.Higaki,T.Shimoto,M.Yoshizumi,Y.Nakanishi,K.Kurata,S.Hamai,H.Miura,Y.Iwamoto
5th World Congress of Biomechanics   157-162   Aug 2006   [Refereed]
Wear Prediction of Polyethylene Insert in Total Knee Arthroplasty
T.Shimoto,H.Higaki,S.Yasutake,T.Ogata,Y.Nakanishi,K.Kurata,H.Miura,Y.Iwamoto
Pros. of the 5th Kobe International Forum Biotribology 2005   35-38   Jun 2005
T. Shimoto, H. Higaki, T. Fukunaga, S. Yasutake, Y. Nakanishi, H. Miura, T. Mawatari, Y. Iwamoto
Proceedings of the IASTED International Conference on Biomechanics   28-33   Jun 2003   [Refereed]
In vivo analysis of the 3-D kinematics of total knee arthroplasty (TKA) is expected as one of the important technique for design of the artificial knee joint in future generation. This study was aimed to develop a 3-D motion analysis with high pre...
Study of motion analysis for total knee arthroplasty using-flat panel detector 'jointly worked'
T.Shimoto,H.Higaki,T.Fukunaga,S.Yasutake,Y.Nakanishi,H.Miura,T.Mawatari,Y.Iwamoto
Proc. of the IASTED International Conference on Biomechanics   28-32   2003

Misc

 
下戸 健
福岡工業大学情報科学研究所所報   24 43-46   Oct 2013
日垣 秀彦, 下戸 健, 白石 善孝
Clinical orthopaedic surgery   46(3) 195-200   Mar 2011
日垣 秀彦, 下戸 健
Common : 総合情報基盤センター広報誌   31(0) 4-9   2011

Conference Activities & Talks

 
小薗直哉, 小薗直哉, 岡田貴充, 竹内直英, 花田麻須大, 下戸健, 日垣秀彦, 宮本知佳, 中西芳応, 千住隆博, 中島康晴
日本整形外科学会雑誌   30 Aug 2018   
小薗直哉, 小薗直哉, 岡田貴充, 竹内直英, 浜井敏, 日垣秀彦, 下戸健, 池部怜, 権藤大貴, 中西芳応, 千住隆博, 中島康晴
日本整形外科学会雑誌   30 Aug 2018   
宇都宮健, 本村悟朗, 久保祐介, 池村聡, 下戸健, 日垣秀彦, 中島康晴
日本整形外科学会雑誌   30 Aug 2018   
千住隆博, 岡田貴充, 竹内直英, 見明豪, 小薗直哉, 中西芳応, 日垣秀彦, 下戸健, 中島康晴
日本整形外科学会雑誌   30 Aug 2018   
平尾泰誠, 安部壮亮, 下戸健, 中山功一, 石川篤, 日垣秀彦
日本機械学会ロボティクス・メカトロニクス講演会講演論文集(CD-ROM)   1 Jun 2018   
葛島航大, 下戸健, 池部怜, 日垣秀彦
日本機械学会ロボティクス・メカトロニクス講演会講演論文集(CD-ROM)   1 Jun 2018   
渡部俊樹, 下戸健, 中山功一, 石川篤, 日垣秀彦
日本機械学会ロボティクス・メカトロニクス講演会講演論文集(CD-ROM)   1 Jun 2018   
小薗直哉, 岡田貴充, 竹内直英, 浜井敏, 日垣秀彦, 王亦峰, 下戸健, 中西芳応, 千住隆博, 中島康晴
整形外科と災害外科   25 Mar 2018   
宮本知佳, 宮地頼太, 下戸健, 石川篤, 日垣秀彦, 見明豪, 小薗直哉, 岡田貴允
バイオエンジニアリング講演会講演論文集(CD-ROM)   13 Dec 2017   
健常肩関節における下垂位内外旋と肩甲骨面挙上の三次元動態解析
小薗 直哉, 岡田 貴充, 竹内 直英, 濱井 敏, 日垣 秀彦, 王 亦峰, 下戸 健, 中西 芳応, 千住 隆博, 中島 康晴
日本肩関節学会抄録集   Oct 2017   
人工股関節全置換術における術中カップ設置角度計測の有用性 イメージマッチング法を用いたコンピューター解析の導入
川原 慎也, 佐藤 太志, 北出 一季, 下戸 健, 園田 和彦, 中村 哲郎, 進 悟史, 日垣 秀彦, 馬渡 太郎, 原 俊彦
日本関節病学会誌   Oct 2017   
腱板修復モデルを使用したSuture bridge法のデザインの違いによる強度の検討
千住 隆博, 岡田 貴充, 竹内 直英, 日垣 秀彦, 下戸 健, 中西 芳応, 中島 康晴
整形外科と災害外科   Oct 2017   
イメージマッチング法を用いた肩関節三次元動態解析 腱板断裂肩と健常肩の比較
千住 隆博, 岡田 貴充, 竹内 直英, 濱井 敏, 小薗 直哉, 日垣 秀彦, 王 亦峰, 下戸 健, 中西 芳応, 中島 康晴
整形外科と災害外科   Oct 2017   
イメージマッチング法を用いた内側開大式高位脛骨骨切り術後の膝関節三次元動態解析
末田 麗真, 川原 慎也, 松井 元, 下戸 健, 井口 貴裕, 光安 浩章, 北出 一季, 馬渡 太郎
整形外科と災害外科   Oct 2017   
イメージマッチング法(DRR)を用いた健常肩関節三次元動態解析 下垂位内外旋と肩甲骨面挙上
小薗 直哉, 岡田 貴充, 竹内 直英, 濱井 敏, 日垣 秀彦, 王 亦峰, 下戸 健, 中西 芳応, 千住 隆博, 中島 康晴
日本整形外科学会雑誌   Aug 2017   
アニマルモデルにおける非対称性core sutureの力学的特性 至適な非対称度の検討
小薗 直哉, 岡田 貴充, 竹内 直英, 花田 麻須大, 下戸 健, 宮地 頼太, 日垣 秀彦, 中西 芳応, 千住 隆博, 中島 康晴
日本整形外科学会雑誌   Aug 2017   
指屈筋腱周囲縫合の強度比較検討 running sutureは断端から対称的に縫合すると強度が高まる
竹内 直英, 岡田 貴充, 花田 麻須大, 見明 豪, 小薗 直哉, 中西 芳応, 千住 隆博, 下戸 健, 日垣 秀彦, 中島 康晴, 岩本 幸英
日本整形外科学会雑誌   Mar 2017   
IKEBE Satoru, WANG Yifeng, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HINO Kazunori, MIURA Hiromasa, HIGAKI Hidehiko
The Proceedings of Conference of Kyushu Branch   2016   
UMENO Takatoshi, SUZUKI Jun, SHIMOTO Takeshi, HIGAKI Hidehiko, IWAMOTO Hideaki
The Proceedings of Conference of Kyushu Branch   2016   
WANG Yifeng, HIGAKI Hidehiko, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, KOZONO Naoya, HAMAI Satoshi, OKADA Takamitsu, IWAMOTO Yukihide
The Proceedings of Conference of Kyushu Branch   2016   
FUJIOKA Yusuke, TASAKI Keisuke, SHIMOTO Takeshi, ISHIKAWA Atsushi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, MIAKE Gou, KOZONO Naoya, OKADA Takamitsu
Robomech   2015   
In performing the finger joint ligament repair, became possible method using anchor. However, cases where the anchor loses have been reported. The purpose of this study was to evaluate about withdraw of anchor under simple tension and cyclic loadi...
YAMASAKI Yuya, FUJIKAWA Marie, MATSUMOTO Tomomi, SIMOTO Takeshi, AKIEDA Shizuka, MIYAZAKI Yudai, NAKAYAMA Koichi, ISHIKAWA Atsushi, HIGAKI Hidehiko
Robomech   2015   
In the field of regenerative medicine, 3-D tissue engineering, which intends to regenerate lost tissues and organs, is mainly focused. We have already established a technique to make a 3-D construct only with cells. Cells construct is made by sphe...
HAYASHIDA Kento, SHIMOTO Takeshi, HIGAKI Hidehiko, OKAMOTO Hidetoshi, MIZUUCHI Hideki, IWAMOTO Yukihide
Robomech   2015   
For the longevity of total knee Replacement (TKR), it is important to predict the wear of polyethylene insert. The aims of this study were to show the mechanical properties of artificial knee joint using computer simulation of KneeSIM, and to eval...
UMENO Takatoshi, SHIMOTO Takeshi, HIGAKI Hidehiko, IWAMOTO Hideaki
SHD   2015   
Speed, agility, and quickness ('SAQ') are important components in most field and team sports but have not been extensively researched in terms of the technical skill of rapidly changing body direction. The purpose of this study was to examine the ...
YAMAMOTO Takayuki, HIGAKI Hidehiko, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2015   
WANG Yifeng, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, HAMAI Satoshi, NAKASHIMA Yasuharu, IWAMOTO Yukihide, HIGAKI Hidehiko
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2015   
SHIMOTO Takeshi, MATSUMOTO Tomomi, YAMASAKI Yuya, FUJIKAWA Marie, AKIEDA Shizuka, MIYAZAKI Yudai, NAKAYAMA Koichi, ISHIKAWA Atsushi, HIGAKI Hidehiko
The Proceedings of Mechanical Engineering Congress, Japan   2015   
We have been working on the development of scaffold free cell delivery system. Cells construct is made by spheroid-culturing the cells and neatly arrange the spheroids. Therefore, reproducible spheroids formation is required. The spheroids are mad...
UMENO Takatoshi, SHINMURA Kentaro, SHIMOTO Takeshi, HIGAKI Hidehiko, IWAMOTO Hideaki, HARADA Kazuhiro
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2015   
HIGAKI Hidehiko, IWAMOTO Yukihide, TESHIMA Yutaro, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2015   
HIGAKI Hidehiko, IWAMOTO Yukihide, YAMAMOTO Takayuki, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2015   
TADAKUMA Yuichi, HARA Mikiko, SHIMOTO Takeshi, TAKEUCHI Naohide, NAKANISHI Yoshitaka, ISHIKAWA Atsushi, HIGAKI Hidehiko
Robomech   2014   
In performing the flexor tendon repair, peripheral suture is essential to improve the sufficient strength and to accomplish the early active mobilization of repaired flexor tendons. It has been reported the interlocking cross-stitch peripheral sut...
HIGAKI Hidehiko, IWAMOTO Yukihide, WANG Yifeng, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2014   
HIGAKI Hidehiko, IWAMOTO Yukihide, WANG Yifeng, IKEBE Satoru, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2014   
IKEBE Satoru, IWAMOTO Yukihide, TESHIMA Yutaro, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2014   
WANG Yifeng, IKEBE Satoru, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, NAKAHARA Hiroyuki, HAMAI Satoshi, IWAMOTO Yukihide
The Proceedings of Conference of Kyushu Branch   2014   
TESHIMA Yutaro, IWAMOTO Yukihide, IKEBE Satoru, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SIMOTO Takeshi, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu
The Proceedings of Conference of Kyushu Branch   2014   
KOJIMAI Takashi, IWAMOTO Yukihide, IKEBE Satoru, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, NAKAHARA Hiroyuki, HAMAI Satoshi
The Proceedings of Mechanical Engineering Congress, Japan   2014   
In the field of biomechanics is performed elucidating motion analysis of normal knee joints. These are not reported motion analysis targeting sports activity Therefore, this study performed in vivo six-degrees-of-freedom motion analysis for natura...
IKEBE Satoru, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, NAKANISHI Yoshitaka, HARA Daisuke, HAMAI Satoshi, NAKASHIMA Yasuharu, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2014   
Hip Osteoarthritis (OA) is often caused by dysplasia and subluxation. Patients with severe OA are operated on total hip arthroplasty (THA). Impingement has been reported after THA and rotational osteotomy. Therefore, the functional assessment of h...
SHIMOTO Takeshi, ADACHI Takahiro, KANEKO Masahiro, IKEBE Satoshi, HIGAKI Hidehiko, HAMAI Satoshi, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2014   
Recently, Impingement problem of femoral component and polyethylene insert after total knee replacement (TKR) has been brought to light by contact pressure analysis using the knee joint simulator. Therefore, adequate motion analysis is important f...
IKEBE Satoru, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, SHIRAISHI Yoshitaka, ISHIMARU Masami, MIURA Hiromasa
The Proceedings of Conference of Kyushu Branch   2013   
KOJIMA Takashi, IKEBE Satoru, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, NISHIMATSU Kazuho, SHIRAISHI Yoshitaka, ISHIMARU Masami, MIURA Hiromasa
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2013   
SATO Yuki, MIYAZAKI Yoshihiro, SHIMOTO Takeshi, NISHIMATSU Kazuho, HIGAKI Hidehiko, HAMAI Satoshi, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2013   
Impingement problem of femoral component and polyethylene insert after total knee arthroplasty (TKA) has been recently brought to light by contact pressure analysis using the knee joint simulator. Therefore, adequate motion analysis is important f...
SHIMOTO Takeshi, TESHIMA Yutaro, IKEBE Satoru, ITO Osamu, HIGAKI Hidehiko, KAWAHARA Shinya, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2013   
After the total knee arthroplasty, it is important to evaluate between the patella component and the femoral component, because patella components affect the flexion angle. There are many types of artificial knee joint. Among them, we focused on t...
NISHIMATSU Kazuho, IWAMOTO Yukihide, IKEBE Satoru, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, SHIRAISHI Yoshitaka, MIURA Hiromasa, NAKAHARA Hiroyuki, HAMAI Satoshi
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2013   
SHIMOTO Takeshi, SHIRAISHI Yoshitaka, ISHIKAWA Atsushi, HIGAKI Hidehiko, MATSUDA Masahiro, MITSUYASU Hiromichi, IWAMOTO Yukihide, MIURA Hiromasa
The Proceedings of Mechanical Engineering Congress, Japan   2012   
In performing the flexor tendon repair, peripheral suture is essential to improve the sufficient strength and to accomplish the early active mobilization of repaired flexor tendons. It has been reported the interlocking cross-stitch peripheral sut...
IKEBE Satoru, SHIMOTO Takeshi, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Conference of Kyushu Branch   2012   
Ikebe Satoru, Higaki Hidehiko, Shimoto Takeshi, Nakanishi Yoshitaka, Shiraishi Yoshitaka, Ishimaru Masami, Miura Hiromasa, TASHIRO Yasutaka, Iwamoto Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2012   
NISHIMATSU Kazuho, SHIMOTO Takeshi, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, YAMAOKA Gotaro, MIURA Hiromasa
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2012   
SHIMOTO Takeshi, Shiraishi Yoshitaka, HIGAKI Hidehiko, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2011   
After the total knee arthroplasty, it is important to evaluate between the patella component and the femoral component, because patella components affect the complications and the flexion angle. The purpose of this study was to investigate the mec...
SHIMOTO Takeshi, NAKAYAMA Koichi, MIYAZAKI Yudai, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
Robomech   2011   
We've been working for developing scaffold free cell delivery system, and show good regeneration of rabbit osteochondral defect until more than three years by implantation of molded mesenchymal stem cells construct without use of exogenous factors...
IKEBE Satoru, SHIMOTO Takeshi, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, NAKANISHI Yoshitaka, MIURA Hiromasa
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2011   
SHIRAISHI Yoshitaka, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, TASHIRO Yasutaka, MIURA Hiromasa, IWAMOTO Yukihide, HARA Toshiaki
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2011   
SHIRAISHI Yoshitaka, IWAO Kotaro, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, TASHIRO Yasutaka, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2011   
SHIRAISHI Yoshitaka, IWAMOTO Yukihide, SATO Makoto, IWAO Kotaro, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, TASHIRO Yasutaka, HAMAI Satoshi, MIURA Hiromasa
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2010   
SHIMOTO Takeshi, NAKAYAMA Koichi, ZHANG Xiu Ying, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
Robomech   2010   
We've been working for developing scaffold free cell delivery system, and show good regeneration of rabbit osteochondral defect until more than three years by implantation of molded mesenchymal stem cells (MSC) construct without use of exogenous f...
IWAO Kotaro, HIGAKI Hidehiko, SHIMOTO Takeshi, SHIRAISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2010   
This study investigated the contact pressure and rotation moment by loading of the femoral component and polyethylene insert in internal/external rotation. Five posterior stabilized prosthesis designs were tested to study using an artificial knee ...
SHIRAISHI Yoshitaka, IWAO Kotaro, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, TASHIRO Yasutaka, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2010   
In biomechanics of the knee joints, the definition of the cruciate ligament adhesion areas is discussed for the cruciate ligament reconstruction. Effective information can be expected to be fed back to the cruciate ligament reconstruction if accur...
SHIMOTO Takeshi, SHIRAISHI Yoshitaka, HIGAKI Hidehiko, TAKEUCHI Naohide, MITSUYASU Hiromichi, MIURA Hiromasa, HOTOKEZAKA Shunsuke, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2010   
In performing the flexor digital tendon repair, peripheral suture is essential to improve the sufficient strength and to accomplish the early active mobilization of repaired flexor tendons. The purpose of this study was to evaluate unrepaired site...
USHIO Keita, IWAMOTO Yukihide, NAKANISHI Yoshitaka, TOUGE Mutsumi, KUBOTA Akihisa, HIGAKI Hidehiko, SHIMOTO Ken, UMENO Takatoshi, SHIRAISHI Yoshitaka, MIURA Hiromasa
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2010   
SHIMOTO Takeshi, SHIRAISHI Yoshitaka, HIGAKI Hidehiko, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2010   
SHIMOTO Takeshi, NAKAYAMA Koichi, ZHANG Xiu Ying, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2010   
SHIMOTO Takeshi, NAKAYAMA Koichi, ZHANQ Xiu Ying, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
Robomech   2009   
We've been working for developing of scaffold free cell delivery system, and show good regeneration of rabbit osteochondral defect until more than two years by implantation of molded mesenchymal stem cells construct without use of exogenous factor...
USHIO Keita, NAKANISHI Yoshitaka, TOUGE Mutsumi, KUBOTA Akihisa, HIGAKI Hidehiko, SHIMOTO Ken, UMENO Takatoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2009   
IWAO Kotaro, HIGAKI Hidehiko, SHIMOTO Takeshi, SHIRAISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2009   
SHIRAISHI Yoshitaka, HIGAKI Hidehiko, SHIMOTO Takeshi, IWAO Kotaro, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2009   
SHIRAISHI Yoshitaka, HIGAKI Hidehiko, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2009   
This study aimed to develop in vivo six-degree-of-freedom (6-DOF) motion analysis for a natural knee joint with high precision using an image matching technique with high-resolution X-ray images from a flat panel detector (FPD). The image matching...
NAKANISHI Yoshitaka, TOUGE Mutsumi, HIGAKI Hidehiko, SHIMOTO Ken, KUGOTA Akihisa, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2009   
Influence of surface roughness on tribological characteristics of ultra-high molecular weight polyethylene (UHMWPE) was investigated by using a pin-on-disc tester. Newly-design surface profile with super-smooth surface and submicron grooves was pr...
UMENO Takatoshi, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, TASHIRO Yasutaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2009   
In order to clarify the effect of a knee support on knee joint kinematics in walking, kinematic gait analysis of 10 young people with intact knees and five young people with unstable anterior cruciate ligaments (ACL) was performed. Three kinematic...
IWAO Kotaro, HIGAKI Hidehiko, SHIMOTO Takeshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2009   
This study investigated the contact pressure of the femoral component and polyethylene insert in internal/external rotation. Two posterior stabilized prosthesis designs were tested to study using an artificial knee joint simulator. The contact pre...
SHIMOTO Takeshi, NAKAYAMA Koichi, ZHANG Xiu Ying, MATSUDA Shuichi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2009   
We've been working for developing scaffold free cell delivery system, and show good regeneration of rabbit osteochondral defect until more than two years by implantation of molded mesenchymal stem cells (MSC) construct without use of exogenous fac...
UMENO Takatoshi, HIGAKI Hidehiko, Nakanishi Yoshitaka, SHIMOTO Takeshi, MIURA Hiromasa
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2009   
YAMAMURA Kunihiko, NAKANISHI Yoshitaka, HIGAKI Hidehiko, UMENO Takatoshi, SHIMOTO Ken
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2009   
SHIRAISHI Yoshitaka, FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2009   
SAYAMA Rie, UMENO Takatoshi, SHIMOTO Takeshi, HIGAKI Hidehiko, NAKANISHI Yoshitaka, MIURA Hiromasa
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2008   
FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2008   
NAKANISHI Yoshitaka, YAMAMURA Kunihiko, SHIMOTO Ken, HIGAKI Hidehiko, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2008   
The relationship between the dissolved oxygen in lubricating liquid and the tribological characteristics of metal-on-metal artificial hip joints was investigated in this study. In a pin made from either a cobalt-chromium-molybdenum (Co-Cr-Mo) allo...
UMENO Takatoshi, HIGAKI Hidehiko, SHIMOTO Takeshi, Nakanishi Yoshitaka, MIURA Hiromasa
The Proceedings of Mechanical Engineering Congress, Japan   2008   
This study demonstrates the knee instability of crusiate ligament deficient knee in walking using knee brace with motion analysis system. Young-male subjects with intact knee crusiate ligament and young-female subject with anterior cruciate ligame...
SHIRAISHI Yoshitaka, FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2008   
This study aimed to develop a three-dimensional motion analysis for a natural knee joint, with high precision in vivo using an image matching technique with high-resolution X-ray image from flat panel detector (FPD). The image matching was perform...
FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIRAISHI Yoshitaka, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2008   
This study was aimed to determine in vivo kneeling kinematics after total knee arthroplasty (TKA). Image matching technique with high-resolutional flat panel detector (FPD) was used for the motion analysis of kneeling and walking. We focused on re...
SHIMOTO Takeshi, SHIRAISHI Yoshitaka, FUKUSHIMA Tatsumi, ARATSU Daikei, HIGAKI Hidehiko, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2008   
This study investigated the mechanisms of anterior impingements of the post with the femoral intercondylar notch. Five posterior stabilized prosthesis designs were tested to study using an artificial knee joint simulator. The contact pressure and ...
SHIRAISHI Yoshitaka, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2008   
FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2008   
ARATSU Daikei, YAMASAKI Hiroaki, HIGAKI Hidehiko, SHIMOTO Takeshi, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2008   
NAKANISHI Yoshitaka, NISHIMURA Tetsuhiro, TAKASHIMA Tatsuki, HIGAKI Hidehiko, SHIMOTO Ken, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2008   
SHIMOTO Takeshi, UOKAWA Satoshi, YOSHIMURA Daisuke, MATSUDA Jyunpei, HIGAKI Hidehiko, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2007   
NAKANISHI Yoshitaka, YAMAMURA Kunihiko, NISHIMURA Tetsuhiro, KAWASAKI Daisuke, SHIMOTO Ken, HIGAKI Hidehiko
The Proceedings of Mechanical Engineering Congress, Japan   2007   
The relationship between the dissolved oxygen in lubricating liquid and the tribological characteristics of metal-on-metal artificial hip joints was investigated in this study. In a pin made from either a cobalt-chromium-molybdenum (Co-Cr-Mo) allo...
SHIMOTO Takeshi, SHIRAISHI Yoshitaka, HIGAKI Hidehiko, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2007   
The study aimed to develop a three-dimensional motion analysis for natural knee joints with high precision in vivo using an image matching technique with a high-resolutional flat panel detector (FPD). Three-dimensional geometry data of the natural...
SHIRAISHI Yoshitaka, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2007   
FUKUSHIMA Tatsumi, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshituka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2007   
YOSHIZUMI Masa-aki, HIGAKI Hidehiko, SHIMOTO Takeshi, UENO Takehiro, FUJIMOTO Takashi, NAKANISHI Yoshitaka, HAMAI Satoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME   2006   
UENO Takehiro, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, MIURA Hiromasa, MATSUDA Syuichi, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2006   
The purpose of this study was to measure the contact area and the contact stress at the post-cam mechanism of posterior-stabilized (PS) total knee arthroplasties (TKAs) when a posterior force of 500N was applied to some PS TKAs. Measurements was m...
SHIMOTO Takeshi, HIGAKI Hidehiko, YOSHIZUMI Masa-aki, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2006   
This study was aimed to determine in vivo walking kinematics of 10 subjects having cruciate-retaining (CR) total knee arthroplasty (TKA). We evaluated knee kinematics during walking activity using image matching technique with high-resolutional fl...
OGATA Takeshi, HIGAKI Hidehiko, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2006   
In this study, we analyzed knee kinematics during stair climbing for cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasties (TKAs). Thirteen knees with CR and four knees with PS TKAs were evaluated using image matching met...
YOSHIZUMI Masa-aki, HIGAKI Hidehiko, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2006   
The purpose of this study was to determine in vivo knee kinematics after total knee arthroplasty(TKA). Subjects were fifteen patients who implanted either cruciate-retaining (CR) or posterior-stabilized (PS) TKAs. All patients were able to walk wi...
SUZAKI Terutaka, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, UMENO Takatoshi, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of Mechanical Engineering Congress, Japan   2006   
When mobile bearing artificial knee joints are designed, little attention has been paid for the dynamic motion of polyethylene insert. Since knee movement involves a complicated combination of translation and rotation, adequate motion analysis is ...
SHIMOTO Takeshi, HIGAKI Hidehiko, YOSHIZUMI Masa-aki, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the Machine Design and Tribology Division meeting in JSME   2006   
Knee movement involves a complicated combination of translations and rotations. Therefore, adequate motion analysis of implanted knee is necessary for estimating the wear of inserts and improving the design of artificial knee joint. This study was...
SHIRAISHI Yoshitaka, HIGAKI Hidehiko, SHIMOTO Takeshi, HAMAI Satoshi, NAKANISHI Yoshitaka, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2006   
SHIMOTO Takeshi, NISIMURA Tetsuhiro, TAKASHIMA Tatsuki, UMENO Takatoshi, NAKANISHI Yoshitaka, HIGAKI Hidehiko, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2006   
YOSHIZUMI Masaaki, HIGAKI Hidehiko, SHIMOTO Takeshi, NAKANISHI Yoshitaka, OGATA Takeshi, ABE Tatsuhiro, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2005   
SUZAKI Terutaka, HIGAKI Hidehiko, SHIMOTO Takeshi, YASUTAKE Seiji, MATUMORI Kenji, OGATA Takeshi, YOSHIZUMI Masaaki, MIURA Hiromasa, IWAMOTO Yukihide
The Proceedings of the JSME Conference on Frontiers in Bioengineering   2005   

Research Grants & Projects

 
Development of Supporting Technology for Total Knee Arthroplasty in Next Generation
The Other Research Programs
Project Year: 2002 - 2005