論文

2021年

Quiet Diffusion-weighted MR Imaging of the Brain for Pediatric Patients with Moyamoya Disease

Magnetic Resonance in Medical Sciences
  • Satoshi Nakajima
  • Yasutaka Fushimi
  • Takeshi Funaki
  • Gosuke Okubo
  • Akihiko Sakata
  • Takuya Hinoda
  • Yusuke Yokota
  • Sonoko Oshima
  • Sayo Otani
  • Takayuki Kikuchi
  • Tomohisa Okada
  • Kazumichi Yoshida
  • Susumu Miyamoto
  • Yuji Nakamoto
  • 全て表示

記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.2463/mrms.mp.2020-0174
出版者・発行元
Japanese Society for Magnetic Resonance in Medicine

PURPOSE: Diffusion-weighted MRI (DWI) is an essential sequence for evaluating pediatric patients with moyamoya disease (MMD); however, acoustic noise associated with DWI may lead to motion artifact. Compared with conventional DWI (cDWI), quiet DWI (qDWI) is considered less noisy and able to keep children more relaxed and stable. This study aimed to evaluate the suitability of qDWI compared with cDWI for pediatric patients with MMD. METHODS: In this observational study, MR examinations of the brain were performed either with or without sedation in pediatric patients with MMD between September 2017 and August 2018. Three neuroradiologists independently evaluated the images for artifacts and restricted diffusion in the brain. The differences between qDWI and cDWI were compared statistically using a chi-square test. RESULTS: One-hundred and six MR scans of 56 patients with MMD (38 scans of 15 sedated patients: 6 boys and 9 girls; mean age, 5.2 years; range, 1-9 years; and 68 scans of 42 unsedated patients: 19 boys and 23 girls; mean age, 10.7 years; range, 7-16 years) were evaluated. MR examinations were performed either with or without sedation (except in one patient). In sedated patients, no artifact other than susceptibility was observed on qDWI, whereas four artifacts were observed on cDWI (P = .04). One patient awoke from sedation during cDWI scanning, while no patient awoke from sedation during qDWI acquisition. For unsedated patients, three scans showed artifacts on qDWI, whereas two scans showed artifacts on cDWI (P = .65). Regarding restricted diffusion, qDWI revealed three cases, while two cases were found on cDWI (P = .66). CONCLUSION: qDWI induced fewer artifacts compared with cDWI in sedated patients, and similar frequencies of artifacts were induced by qDWI and by cDWI in unsedated patients. qDWI showed restricted diffusion comparable to cDWI.

リンク情報
DOI
https://doi.org/10.2463/mrms.mp.2020-0174
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/34334585
URL
https://www.jstage.jst.go.jp/article/mrms/advpub/0/advpub_mp.2020-0174/_pdf
ID情報
  • DOI : 10.2463/mrms.mp.2020-0174
  • ISSN : 1347-3182
  • eISSN : 1880-2206
  • PubMed ID : 34334585

エクスポート
BibTeX RIS