Continued from the previous study, a plywood nailed joint specimen with the nails rusting was tested by cyclic and dynamic load. In addition, the shear walls with the nails rusting were tested. As a result, the following was provided.<br>1. The nails was liable to break in cyclic load than monotonic load.<br>2. As the weight remaining rate of nails decrease, the dynamic effects become remarkable and the strength increase.<br>3. The allowable shear performance calculated by the dynamic test has a tendency to be equal to or greater than the static test.<br>4. When the weight remaining rate of nails is about 98%, the allowable shear performance shows higher value than without rusting.<br>5. It is possible to apply the estimating methods for the racking load of the shear wall to the walls with the nails rusting.