論文

査読有り 本文へのリンクあり
2018年1月1日

Vibration isolation system for cryocoolers of soft x-ray spectrometer on-board ASTRO-H (Hitomi)

Journal of Astronomical Telescopes, Instruments, and Systems
  • Yoh Takei
  • Susumu Yasuda
  • Kosei Ishimura
  • Naoko Iwata
  • Atsushi Okamoto
  • Yoichi Sato
  • Mina Ogawa
  • Makoto Sawada
  • Taro Kawano
  • Shingo Obara
  • Chikara Natsukari
  • Atsushi Wada
  • Shinya Yamada
  • Ryuichi Fujimoto
  • Motohide Kokubun
  • Noriko Y. Yamasaki
  • Hiroyuki Sugita
  • Kenji Minesugi
  • Yasuo Nakamura
  • Kazuhisa Mitsuda
  • Tadayuki Takahashi
  • Seiji Yoshida
  • Shoji Tsunematsu
  • Kenichi Kanao
  • Katsuhiro Narasaki
  • Kiyomi Otsuka
  • F. Scott Porter
  • Caroline A. Kilbourne
  • Meng P. Chiao
  • Megan E. Eckart
  • Gary A. Sneiderman
  • James T. Pontius
  • Dan McCammon
  • Paul Wilke
  • John Basile
  • 全て表示

4
1
開始ページ
011216
終了ページ
記述言語
掲載種別
研究論文(学術雑誌)
DOI
10.1117/1.JATIS.4.1.011216

© The Authors 2018. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. The soft x-ray spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a microcalorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from microvibration from cryocoolers mounted on the dewar. This is mitigated for the flight model (FM) by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the FM was verified before launch of the spacecraft in both ambient condition and thermal-vacuum condition, showing no detectable degradation in energy resolution. The in-orbit detector spectral performance and cryocooler cooling performance were also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the microvibration could degrade the cryogenic detector is shown. Lessons learned from the development to mitigate unexpected issues are also described.

リンク情報
DOI
https://doi.org/10.1117/1.JATIS.4.1.011216
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85042460282&origin=inward 本文へのリンクあり
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85042460282&origin=inward
URL
https://ui.adsabs.harvard.edu/#abs/2018JATIS...4a1216T
ID情報
  • DOI : 10.1117/1.JATIS.4.1.011216
  • ISSN : 2329-4124
  • eISSN : 2329-4221
  • SCOPUS ID : 85042460282

エクスポート
BibTeX RIS