論文

査読有り
2016年10月

A rapid and reliable technique for N-nitrosodimethylamine analysis in reclaimed water by HPLC-photochemical reaction-chemiluminescence

CHEMOSPHERE
  • Takahiro Fujioka
  • ,
  • Haruka Takeuchi
  • ,
  • Hiroaki Tanaka
  • ,
  • Long D. Nghiem
  • ,
  • Kenneth P. Ishida
  • ,
  • Hitoshi Kodamatani

161
開始ページ
104
終了ページ
111
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.chemosphere.2016.06.094
出版者・発行元
PERGAMON-ELSEVIER SCIENCE LTD

A fast and reliable analytical technique was evaluated and validated for determination of N-nitrosodimethylamine (NDMA) formation and rejection by reverse osmosis (RO) membranes in potable water reuse applications. The analytical instrument used in this study is high-performance liquid chromatography (HPLC), photochemical reaction (PR) and chemiluminescence (CL) namely HPLC-PR-CL. Results reported here show that HPLC-PR-CL can be used to measure NDMA with a similar level of accuracy compared to conventional and more time-consuming techniques using gas chromatography and tandem mass spectrometry detection in combination with solid phase extraction. Among key residual chemicals (i.e. monochloramine, hydrogen peroxide and hypochlorite) in reclaimed wastewater, hypochlorite was the only constituent that interfered with the determination of NDMA by HPLC-PR-CL. However, hypo chlorite interference was eliminated by adding ascorbic acid as a reducing agent. Direct injection of ultrafiltration (UF)-treated wastewater samples into HPLC-PR-CL also resulted in an underestimation of the NDMA concentration possibly due to interference by organic substances in the UF-treated wastewater. Accurate determination of NDMA concentrations in UF-treated wastewater was achieved by reducing the sample injection volume from 200 to 20 mu L, though this increased the method detection limit from 0.2 to 2 ng/L. In contrast, no interference was observed with RO permeate. These results suggest that RO membranes could remove part of substances that interfere with the NDMA analysis by HPLC-PR-CL. In addition, RO treatment experiments demonstrated that HPLC-PR-CL was capable of evaluating near real-time variation in NDMA rejection by RO. (C) 2016 Elsevier Ltd. All rights reserved.

リンク情報
DOI
https://doi.org/10.1016/j.chemosphere.2016.06.094
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000382409200012&DestApp=WOS_CPL
ID情報
  • DOI : 10.1016/j.chemosphere.2016.06.094
  • ISSN : 0045-6535
  • eISSN : 1879-1298
  • Web of Science ID : WOS:000382409200012

エクスポート
BibTeX RIS