Cybernic treatment with wearable cyborg Hybrid Assistive Limb (HAL) improves ambulatory function in patients with slowly progressive rare neuromuscular diseases: a multicentre, randomised, controlled crossover trial for efficacy and safety (NCY-3001).

Orphanet journal of rare diseases
  • Nakajima Takashi
  • Sankai Yoshiyuki
  • Takata Shinjiro
  • Kobayashi Yoko
  • Ando Yoshihito
  • Nakagawa Masanori
  • Saito Toshio
  • Saito Kayoko
  • Ishida Chiho
  • Tamaoka Akira
  • Saotome Takako
  • Ikai Tetsuo
  • Endo Hisako
  • Ishii Kazuhiro
  • Morita Mitsuya
  • Maeno Takashi
  • Komai Kiyonobu
  • Ikeda Tetsuhiko
  • Ishikawa Yuka
  • Maeshima Shinichiro
  • Aoki Masashi
  • Ito Michiya
  • Mima Tatsuya
  • Miura Toshihiko
  • Matsuda Jun
  • Kawaguchi Yumiko
  • Hayashi Tomohiro
  • Shingu Masahiro
  • Kawamoto Hiroaki
  • 全て表示

16
1
開始ページ
304
終了ページ
304
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1186/s13023-021-01928-9

BACKGROUND:Rare neuromuscular diseases such as spinal muscular atrophy, spinal bulbar muscular atrophy, muscular dystrophy, Charcot-Marie-Tooth disease, distal myopathy, sporadic inclusion body myositis, congenital myopathy, and amyotrophic lateral sclerosis lead to incurable amyotrophy and consequent loss of ambulation. Thus far, no therapeutic approaches have been successful in recovering the ambulatory ability. Thus, the aim of this trial was to evaluate the efficacy and safety of cybernic treatment with a wearable cyborg Hybrid Assistive Limb (HAL, Lower Limb Type) in improving the ambulatory function in those patients.RESULTS:We conducted an open-label, randomised, controlled crossover trial to test HAL at nine hospitals between March 6, 2013 and August 8, 2014. Eligible patients were older than 18 years and had a diagnosis of neuromuscular disease as specified above. They were unable to walk for 10 m independently and had neither respiratory failure nor rapid deterioration in gait. The primary endpoint was the distance passed during a two-minute walk test (2MWT). The secondary endpoints were walking speed, cadence, and step length during the 10-m walk test (10MWT), muscle strength by manual muscle testing (MMT), and a series of functional measures. Adverse events and failures/problems/errors with HAL were also evaluated. Thirty patients were randomly assigned to groups A or B, with each group of 15 receiving both treatments in a crossover design. The efficacy of a 40-min walking program performed nine times was compared between HAL plus a hoist and a hoist only. The final analysis included 13 and 11 patients in groups A and B, respectively. Cybernic treatment with HAL resulted in a 10.066% significantly improved distance in 2MWT (95% confidence interval, 0.667-19.464; p = 0.0369) compared with the hoist only treatment. Among the secondary endpoints, the total scores of MMT and cadence at 10MWT were the only ones that showed significant improvement. The only adverse effects were slight to mild myalgia, back pain, and contact skin troubles, which were easily remedied.CONCLUSIONS:HAL is a new treatment device for walking exercise, proven to be more effective than the conventional method in patients with incurable neuromuscular diseases.TRIAL REGISTRATION:JMACTR, JMA-IIA00156.

リンク情報
DOI
https://doi.org/10.1186/s13023-021-01928-9
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/34233722
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8261928
ID情報
  • DOI : 10.1186/s13023-021-01928-9
  • ISSN : 1750-1172
  • PubMed ID : 34233722
  • PubMed Central 記事ID : PMC8261928

エクスポート
BibTeX RIS