論文

国際誌
2022年8月1日

Dose length product and outcome of CT fluoroscopy-guided interventions using a new 320-detector row CT scanner with deep-learning reconstruction and new bow-tie filter.

The British journal of radiology
  • Tomohiro Matsumoto
  • Kazuyuki Endo
  • Shota Yamamoto
  • Satoshi Suda
  • Kosuke Tomita
  • Shunsuke Kamei
  • Terumitsu Hasebe
  • Kazuo Awai
  • Kensuke Osaragi
  • Rika Yoshimatsu
  • Takuji Yamagami
  • 全て表示

95
1136
開始ページ
20211159
終了ページ
20211159
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1259/bjr.20211159

OBJECTIVES: To investigate the dose length product (DLP) and outcomes of CT fluoroscopy (CTF)-guided interventions using a novel 320-detector row CT scanner with deep-learning reconstruction (DLR) and a new bow-tie filter (i.e., Aquilion ONE Prism Edition) and compare with a 320-detector row CT system without DLR and the new bow-tie filter (i.e., Aquilion ONE Vision Edition) (Vision). METHODS: CTF-guided interventions performed using Prism and Vision were retrospectively investigated in terms of the technical success rates, clinical success rates of biopsies, complications, DLPs of total CT scans (total DLPs) from February 2019 to January 2021. The total CT scans included pre-interventional CT scans, CTF scans during the CTF-guided procedure, additional CT scans for additional treatment, CTF scans for additional treatment, and post-interventional CT scans. RESULTS: In this study, 87 and 85 CTF-guided interventions were performed using Vision (Vision group) and Prism (Prism group), respectively. There was no significant difference in the technical success rate (96.6% vs 98.8%, p = 0.621), clinical success rate of biopsies (92.9% vs 93.4%, p = 1.000), and minor (8.0% vs 7.1%, p = 0.807) and major (0% vs 3.5%, p = 0.119) complications between the Prism and Vision groups. The total DLPs for the Prism group were significantly lower than those for the Vision group regardless of the procedure (278 vs 548 mGy*cm, p < 0.001, in the biopsy and 246 vs 667 mGy*cm, p < 0.001, in the drainage and aspiration). CONCLUSIONS: CTF-guided interventions on Prism reduce the total DLP without performance degradation of the intervention. ADVANCES IN KNOWLEDGE: The total DLPs of biopsies and drainages/aspirations in the Prism group decreased by 49 and 63%, respectively.

リンク情報
DOI
https://doi.org/10.1259/bjr.20211159
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/35671099
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10162057
ID情報
  • DOI : 10.1259/bjr.20211159
  • PubMed ID : 35671099
  • PubMed Central 記事ID : PMC10162057

エクスポート
BibTeX RIS