論文

査読有り 国際誌
2020年3月

Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals.

European radiology
  • Toshiyuki Komaki
  • Takao Hiraki
  • Tetsushi Kamegawa
  • Takayuki Matsuno
  • Jun Sakurai
  • Ryutaro Matsuura
  • Takuya Yamaguchi
  • Takanori Sasaki
  • Toshiharu Mitsuhashi
  • Soichiro Okamoto
  • Mayu Uka
  • Yusuke Matsui
  • Toshihiro Iguchi
  • Hideo Gobara
  • Susumu Kanazawa
  • 全て表示

30
3
開始ページ
1342
終了ページ
1349
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1007/s00330-019-06477-1

OBJECTIVES: To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments. METHODS: A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student's t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center. RESULTS: In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively. CONCLUSION: Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion. KEY POINTS: • Out-of-plane needle insertions performed using our robot were more accurate than smartphone-guided manual insertions in the phantom experiment and were also accurate in the in vivo procedure. • In the phantom experiment, the mean angle errors of the robotic and smartphone-guided manual out-of-plane needle insertions were 0.4° and 3.7° in the XY plane (p < 0.001) and 0.6° and 0.6° in the YZ plane (p = 0.65), respectively. • In the animal experiment, the overall mean distance accuracies of the robotic out-of-plane needle insertions with and without adjustments of needle orientation during insertion were 2.5 mm and 5.0 mm, respectively.

リンク情報
DOI
https://doi.org/10.1007/s00330-019-06477-1
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/31773299
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7033049
ID情報
  • DOI : 10.1007/s00330-019-06477-1
  • ISSN : 0938-7994
  • PubMed ID : 31773299
  • PubMed Central 記事ID : PMC7033049

エクスポート
BibTeX RIS