論文

査読有り 国際誌
2020年5月1日

Simple and reliable enumeration of Escherichia coli concentrations in wastewater samples by measuring β-D-glucuronidase (GUS) activities via a microplate reader

Science of the Total Environment
  • Hisashi Satoh
  • Kai Kikuchi
  • Yutaka Katayose
  • Shu Tsuda
  • Reiko Hirano
  • Yuga Hirakata
  • Masaaki Kitajima
  • Satoshi Ishii
  • Mamoru Oshiki
  • Masashi Hatamoto
  • Masahiro Takahashi
  • Satoshi Okabe
  • 全て表示

715
開始ページ
136928
終了ページ
136928
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1016/j.scitotenv.2020.136928
出版者・発行元
ELSEVIER

© 2020 Elsevier B.V. Monitoring of Escherichia coli concentrations at wastewater treatment plants (WWTPs) is important to ensure process performance and protect public health. However, conventional E. coli enumeration methods are complicated and time- and labor-consuming. Here, we report a novel simple and reliable method based on β-D-glucuronidase (GUS) activity assay to enumerate E. coli concentrations in wastewater (WW) samples. An aliquot (20 μL) of the medium with fluorogenic enzyme substrate for E. coli and 180 μL of a WW sample were added to one well of a 96-well microplate. The microplate was placed in a microplate reader at 37 °C. To this end, the fluorescence intensity of a fluorogenic enzyme substrate for E. coli was measured every 10 min over 3 h to determine GUS activity. The linear increase in the fluorescence intensity representing the GUS activities showed a positive correlation with E. coli concentrations in wastewater samples. However, the correlation equations were specific to WWTPs, which could be due to the difference in the E. coli population structures among WWTPs. We observed that the wastewater matrix is not a limitation to measure the GUS activity, and a WWTP-specific correlation equation can be used as a calibration curve to estimate the E. coli concentrations in the samples collected from that site. A comparison of the results with those of culture-dependent Colilert method proved that the current method is simple and useful for the enumeration of E. coli concentrations in wastewater samples reliably.

リンク情報
DOI
https://doi.org/10.1016/j.scitotenv.2020.136928
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/32007893
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000518409900127&DestApp=WOS_CPL
Scopus
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85078434326&origin=inward
Scopus Citedby
https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85078434326&origin=inward
ID情報
  • DOI : 10.1016/j.scitotenv.2020.136928
  • ISSN : 0048-9697
  • eISSN : 1879-1026
  • PubMed ID : 32007893
  • SCOPUS ID : 85078434326
  • Web of Science ID : WOS:000518409900127

エクスポート
BibTeX RIS