KONDO Yasushi

J-GLOBAL         Last updated: Oct 9, 2019 at 10:29
 
Avatar
Name
KONDO Yasushi
Affiliation
Tokyo City University
Section
Faculty of EngineeringDepartment of Architecture
Job title
Professor
Degree
(BLANK)(The University of Tokyo), (BLANK)(Kobe University)

Research Areas

 
 

Published Papers

 
LOAD CALCULATION METHOD BASED ON HEAT BALANCE MODEL IN BLOCKS, Estimation method of cooling load due to train wind in an underground station: Part 3
Kentaro KIMURA, Naoyuki TANITA, Makoto SATOH, Masafumi SATO, Katsuhiko SHIBATA and Yasushi KONDO
JOURNAL OF ENVIRONMENTAL ENGINEERING(Transaction of AIJ)   Vol.84(No.757) 313-321   Mar 2019   [Refereed]
Calculation Method for Cooling Load in an Underground Station Using of Estimated Air Temperature in Tunnnels
Katsuhiko Shibata, Kentaro Kimura, Masafumi Sato and Yasushi Kondo
Report of Research and Development Center of Takasago Thermal Engineering Co., Ltd.   No.32(No.32)    Dec 2018
DISPLACEMENT VENTILATION SYSTEM WITH CELLING MOUNTED DIFFUSERS IN A GAS COMMERCIAL KITCHEN
Atsushi OKUDA, Yasushi KONDO, Hajime YOSHINO, Shinji YAMASHITA and Tomoyuki KAWAZOE
Journal of Environmental Engineering ( Tranaction of AIJ )   Vol.83(No.752) 839-849   Oct 2018   [Refereed]
Ventilation Planning for Mid-sized Japanese Commercial Kitchens and Calculation Method of Ventilation Rate Using Building Information Modeling
Osamu Nagase , Yasushi Kondo, Hajime Yoshino, Miwako Fujita and Shunsuke Ogita
The 39th AIVC(Air Infiltration and Ventilation Center) conference   Vol. 39(No.1)    Sep 2018   [Refereed]
ESTIMATION METHOD FOR COOLING LOAD CAUSED BY TRAIN WIND IN AN UNDERGROUND STATION Part 2 SIMPLE ESTIMATION FORMULA OF AIR TEMPERATURE IN TUNNELS
Kentaro Kimura, Katsuhiko Shibata, Masafumi Sato, Naoyuki Tanita, Hidetaka Yagi and Yasushi Kondo
Journal of Environmental Engineering Transaction of AIJ   Vol.83(No.749) 607-613   Jul 2018   [Refereed]
ACTUAL INSULATION PERFORMACE AND DESIGN THERMAL CONDUCTVITY OF ALC PANELS
Yoshikatsu MIZUTANI, Yasushi KONDO, Tsuyoshi SEIKE, Akio KOYAMA, Tetsuo FUJIMOTO, Tohru MIYAUCHI
AIJ Journal of Technology and Design   Vol. 24(No. 57) 709-714   Jun 2018   [Refereed]
Overview and Features of Plastic foam spray insulation material
Yasushi Kondo
Heat and Environment   Vol.29(Summer)    Jul 2017
Study on Design Method of Commercial Kitchen Ventilation in Medium-sized Electrical Commercial Kitchens Part 3 Estimation Method of Design Load Factor for Kitchen Appliances
Osamu NAGASE, Yasushi KONDO, Miwako FUJITA, Hajime YOSHINO and Shunsuke OGITA
Journal of SHASE   No.231(No.231)    Jun 2016   [Refereed]
CFD Simulation of Thermal Plume over a Cooking Range with Disturbance Due to a Moving Body
Yasushi Kondo and Takahiro Ishiwata
Transaction of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan   No.224(No.224) 57-62   Nov 2015   [Refereed]
Thermal Environment and Energy Conservation in a Small Kitchen of a Convenience Store
Yasushi KONDO,Takashi NISHIO,Hisashi OGURA,Kenji UEYAMA, Yoshio OZAWA, Koichi TANIYAMA
Transaction of SHASEJ   No.221(No.221) 31-38   Aug 2015   [Refereed]
ESTIMATION METHOD OF COOLING LOAD DUE TO TRAIN WIND IN AN UNDERGROUND STATION
Kentaro KIMURA, Katsuhiko SHIBATA, Naoyuki TANITA, Masafumi SATO and Yasushi KONDO
Journal of Environmental Engineering ( Transactions of AIJ )   Vol.80(No.714) 657-664   Aug 2015   [Refereed]
Study of the design method of commercial kitchen ventilation in medeium-sized electrical commercial kitchens Part 2 Survey of kitchen dimensions, exhaust hood, supply openings and kitchen appliances
Osamu Nagase, Yasushi Kondo, Miwako Fujita, Hajime Yoshino and Shunsuke Ogita
Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan   No.216(No.216)    Mar 2015   [Refereed]
Expriments and CFD simulations on Ventilation Route in Bedrooms of Houses with Central-Exhaust Ventilation Systems
Yasushi Kondo, Kyohei Ota, Hisashi Ogura, Kensuke Yokota andShin Hayakawa
Journal of SHASE   No.215(No.215)    Feb 2015   [Refereed]
Indoor Air Environment of Commercial Kitchens
Yasushi Kondo
Journal of Japan Air Cleaning Association   Vol.52(No.5) 342-348   Jan 2015
Improvement Method of Thermal Environment in Washing Area of Commercial Kitchens
Yasushi Kondo, Kyohei Ota, Hironori Komatsu and Atsushi Okuda
Journal of SHASE   No.212(No.212)    Nov 2014   [Refereed]
Study on Design Method of Commercial Kitchen Ventilation Part 1 Field Measurement of Airflow Disturbance around Exhaust Hoods
Shunsuke OGITA, Yasushi KONDO, Miwako FUJITA, Hajime YOSHINO and Osamu NAGASE
Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan   No.211(No.211)    Oct 2014   [Refereed]
FIELD SURVEY ON FREQUENCY OF COOKING OPERATIONS AND
Yasushi KONDO, Yoshihiro Saito, Hajime YOSHINO, Shunsuke OGITA and Miwako FUJITA
Journal of environmental engineering (Transaction of AIJ)   Vol.79(No.698) 323-329   Apr 2014   [Refereed]
MOVING SPEED AND FREQUENCY OF A PANEL TO SIMULATE AIR TURBULENCE CAUSED BY COOKING OPERATIONS IN HOOD CAPTURE EFFICIENCY TEST FOR COMMERCIAL KITCHENS
Yasushi Kondo, Hirohito Iwasaki, Hajime Yoshino, Shunsuke Ogita and Miwako Fujita
Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan   No.204(No.204) 77-83   Mar 2014   [Refereed]
Commercial Kitchen Ventilation in Casual Restaurants (Part 2) COMPARISON BETWEEN CONVENTIONAL SYSTEM AND DISPLACEMENT VENTILATION SYSTEM WITH CEILING SUPPLY OPENINGS BY FIELD MEASUREMENT IN A REAL KITCHEN
Shunsuke Ogita, Yasushi Kondo, Hajime Yoshino and Miwako Fujita
Journal of environmental engineering (Transaction of AIJ)   Vol. 7(No,697) 247-254   Mar 2014   [Refereed]
Study on lmprovement of Air Quality in Smoking Areas of Restaurants Part 2 Experirrlents and WIoving Body CFD Silllulation
Yasushi Kondo, Shin-ya Uemura, Minku Kim and Takuya Asai
Journal of SHASE   Vol.195(No.195) 19-26   Jun 2013   [Refereed]
Study on Ventilation Routes in Dwelling Houses with Central-Exhaust Ventilation Systems
Shin Hayakawa, Yasushi Kondo and Kyohei Ota
Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan   No.192(No.192) 31-34   Mar 2013   [Refereed]
Cpmbined Effect of Insulation and Solar Refectance of Roof on Attic Temperature
Yasushi Kondo, Taira Aoki, Kyohei Ota, Tomoyuki Nagayoshi and Hiroki Otsuka
AIJ Journal of Technology and Design   Vol.19(N0.41) 203-208   Feb 2013   [Refereed]
Mitigation of Heat Island by Increasing Solar Reflectance of Urban Surface
Yasushi Kondo
JTCCM Journal   Vol.49(No.1) 26-32   Jan 2013
Study on displacement ventilation system in an electrical commercial kitchen
Kondo Yasushi, Ogita ShunsukeYoshino Hajime and Fujita Miwako
Journal of environmental engineering (Transaction of AIJ)   Vol.77(No.676) 481-489   Jun 2012   [Refereed]
Study of Improvement Air Quality in Smoking Area of Restaurants Part 1 CFD Simulation on comvined system of local ventilation and displacement ventilation in smoking area of restaurants
Yasushi Kondo, Shin-ya Uemura and Minku Kim
Journal of SHASE   No.182(No.182)    May 2012   [Refereed]
Development of airflow data for CFD simulation with an air diffuser model and its application (Part 1) Factors of airflow distribution from system ceiling air diffusers and its unstructured fine elements CFD simulation
Yasuhiro Nagasawa and Yasushi Kondo
Journal of environmental engineering (Transaction of AIJ)   Vol.77(No.672) 55-64   Feb 2012   [Refereed]
Indoor temperature and air distribution of house kitchens and adjacent living rooms (Part 3) CFD simulation on kitchen layout, shape of echaust hood and heating system
Yasushi Kondo, Yukiko Abe, Shoko Fujino and Kyohei Ohta
Journal of Environmental Engineering ( Transaction of AIJ)   Vol.76(No.669) 963-972   Nov 2011   [Refereed]
P.V. method as CFD modeling of ceiling air diffuser and its application
Yasushi Kondo, Fab Zhao, Kyohei Ota and Yasuhiro Nagasawa
Journal of Environmental Engineering ( Transaction of AIJ)   Vol.76(No.667) 785-792   Sep 2011   [Refereed]
Measurement of IAQ in classrooms of metropolitan high school and CFD simulation on HVAC system to improve IAQ
Hisashi YOMOGIDA, Yuki Iwase, Yasushi KONDO, Takayuki FUJIWARA
AIJ Journal of Technology and design   Vo. 17(No. 36) 583-587   Jun 2011   [Refereed]
Particle size distribution and aerosol dynamics of oil mist in commercial kitchens
Yasushi Kondo, Akinobu Kawaguchi, Hajime Yoshino and Shunsuke Ogita
Journal of Environmental Engineering ( Transaction of AIJ)   Vol. 76(No. 664) 547-554   Jun 2011   [Refereed]
Study on chenge of performance by outdoor exposure of reflective paints
Taisuke ITO, Hitoshi TAKEDA, Tetsuo FUJIMOTO, Yasushi KONDO, Yasunobu ASHIE
AIJ Journal of Technology and design   Vol.17(No.35) 217-220   Feb 2011   [Refereed]
IMPROVEMENT OF INDOOR THERMAL ENVIONMENT IN METROPOLITAN HIGH SCHOOLS
Hisashi YOMOGIDA, Yasushi KONDO, Takayuki FUJIWARA
AIJ Journal of Technology and design   Vol.17(No.35) 205-210   Feb 2011   [Refereed]
Simple evaluation system of Cool roof for proper promotion Part 2 DEVELOPMENT OF EVALUATION TOOL FOR PUBLIC BENEFIT
Hideki TAKEBAYASHI, Yasushi KONDO
AIJ Journal of Technology and design   Vol.16(No.33) 589-594   Jun 2010   [Refereed]
Study on Displacement Ventilation in a Large-scale Food Factory Part 1-Field Measurement on Indoor Thermal Environment in Summer and Moderate Seasons
Jinya Takeuchi, Hajime Yoshino, Shunsuke Ogita, Kazuhide Ito, Norikazu Nakagawa, Yoshihiro Takahashi and Yasushi Kondo
Journal of SHASE   Vol.156(Vol.156) 19-27   Mar 2010   [Refereed]
Study on displacement ventilation system in commercial kitchens (Part 2) Compaison between conventional HVAS system and displacement ventilation system with ceiling supply outlet
Shunsuke Ogita, Yasushi Kondo, Hajime Yoshino and Koichi Nishikawa
Journal of Environmental Engineering ( Transaction of AIJ)   Vol.75(No.648) 179-187   Feb 2010   [Refereed]
Short Circuit Ratio of HVAC System Based on CFD Simulation
Kyohei Ota and Yasushi Kondo
Journal of SHASE   Vol.145(No.145) 29-34   Apr 2009   [Refereed]
Treatment of Solar Radiation in CFD Simulation and Several Case Studies
Hiroyuki Mishima, Yasushi Kondo and Hajime Yoshino
Journal of SHASE   Vol.145(No.145) 35-41   Apr 2009   [Refereed]
INFLUENCE OF RADIATION REFLECTED BY COOL PAVEMENT ON THERMAL SENSATION OF PEDESTRIANS Reduction of sensible heat emission by cool pavement as countermeasure of heat island (Part 2)
Yasushi Kondo, Takeshi Ogasawara and Kunihiro Udoh
Journal of AIJ   Vol.74(No.637) 323-330   Mar 2009   [Refereed]
EXPERIMENTS ON PERIMETERLESS SYSTEM FOR DISPLACEMENT VENTILATION UNDER HEATING CONDITION Study on displacement ventilation in non-industrial premises Part 1
Hidetsugu Sasaki, Hajime Yoshino, Jinya Takeuchi and Yasushi Kondo
Journal of AIJ   Vol.74(No.636) 201-208   Feb 2009   [Refereed]
EXPERIMENTAL STUDY ON SOUND INSULATION AND ABSORPTION METHODS IN OPEN TYPE CLASSROOMS
Megumi Omori, Kiyoshi Sugino and Yasushi Kondo
AIJ JOURNAL OF TECHNOLOGY AND DESIGN   Vol.15(No.31) 779-784   2009   [Refereed]
MEASUREMENTS AND NUMERICAL SIMULATIONS ON LONG TERM THERMAL PERFORMANCE OF PLASTIC INSULATION FOAMS
Yasushi Kondo, Yasuhiro Nagasawa, Tetsuo Fujimoto and Taichi Tasaka
Journal of AIJ   Vol.73(No.634) 1361-1368   Dec 2008   [Refereed]
CFD MODELINGOF THERMAL PLUME OVER A COOKING POT AND EXPERIMENTS UNDER HEATING CONDITION Indoor temperature and air distributions of house kitchens and adjacent living rooms (Part 2)
Yasushi Kondo, Yukiko Abe, Akira Miyafuji, Yoshihiro Aizawa and Katsuyoshi AKAGI
Journal of AIJ   Vol.73(No.634) 1383-1390   Dec 2008   [Refereed]
Cool roof saves energy for cooling system and mitigates heat island phenomena
Yasushi Kondo
Reform   Vol.25(No.295) 13-17   Oct 2008
REDUCTION OF SENSIBLE HEAT EMISSION BY INCREASING ROOF SOLAR REFLECTANCE AS A COUNTERMEASURE OF HEAT ISLAND PHENOMENA
Yasushi Kondo, Takeshi Ogasawara, Taisuke Ohki and Kunihiro Udoh
Journal of AIJ   Vol.73(No.629) 923-929   Jul 2008   [Refereed]
HVAC System and Work Environment in Commertial Kitchens
Yasushi Kondo
BUILDING MECHANICAL AND ELECTRICAL   Vol.40(No.7)    Jul 2008
CASE STUDIES OF EFFECTIVE VENTILATED VOLUME BASED ON CFD SIMULATIONS Definition and evaluation method of effective ventilated Volume in rooms (Part 2)
Yasushi Kondo, Yukiko Abe and Hajime Yoshino
Journal of AIJ   Vol.73(No.628) 743-750   Jun 2008   [Refereed]
EXPERIMENTS AND CFD SIMULATIONS ON DISPLACEMENT VENTILATION SYSTEM WITH CEILING SUPPLY OUTLET Study on displacement ventilation system in commercial kitchens (Part 1)
Shunsuke Ogita, Yasushi Kondo, Hajime Yoshino, Takaharu Kawase and Toshiaki Hirata
Journal of AIJ   Vol.73(No.628) 759-766   Jun 2008   [Refereed]
Cool pavement mitigates heat island phenomena and increases radiation to human bodies from pavement
Yasushi Kondo, Takeshi Ogasawara, Hiroshi Kanamori
HOSOU   Vol.43(No.6) 24-30   Jun 2008
FIELD MEASUREMENTS AND HEAT BUDGET ANALYSIS ON SENSIBLE HEAT FLUX FROM PAVEMENT Reduction of sensible heat emission by cool pavement as countermeasure of heat island (Part 1)
Yasushi Kondo, Takeshi Ogasawara amd Hiroshi Kanamori
Journal of AIJ   Vol.73(No.628) 791-797   Jun 2008   [Refereed]
EXPERIMENTS ON INFFUENCE OF AIR SUPPLY POSITION AND DISTURBANCE WITH COOKING OPERATION ON INDOOR ENVIRONMENT Indoor temperature and air distributions of house kitchens and adjacent living rooms (Part 1)
Yasushi Kondo, Yukiko Abe, Takanori Oshima and Yoshihiro Aizawa
Journal of AIJ   Vol.73(No.627) 607-614   May 2008   [Refereed]

Misc

 
An Analytical Solution of Heat and Moisture Transter In The Multi-Layered Hygroscopic Wall In The Steady Periodic State
Journal of Architecture, Planning and Environmental Engineering   (347)    1985
Examining k-ε EVM by means of ASM on a 3-D horizontal buoyant jet in enclosed space,
Engineering Turbulence Modelling and Experiments      1990
Room airflow analysis by means of algebraic stress model (Part 1), comparison Between Algebraic Stress Model and k-ε Model Concerned with Isothermal Two-Dimensional Room Airflow
Jaurnal of Architecture, Planning and Environmental Engineering   (415)    1990
Room airflow analysis by means of algebraic Stress model (Part2), 2-D Numerical Study of Passive Scalar Diffusion Field and Now-Isothermal Flow Field
Journal of Architecture, Planning and Environmental Engineering   (421)    1991
Room airflow analysis by means of algebraic Stress model (Part3), Numerical Study of Isothermal Three-Dimensional Room Airflow
Journal of Architecture, Planning and Environmental Engineering   (429)    1991

Conference Activities & Talks

 
Evaluation Method of Complicated Shape Insulation Foam Part 2 Safe Side Estimation of Thermal Resistance with Heated Box Test
O. Suzuki, Y. Nagaswa, Y. Kondo and S. Hagiwara
Annual Meeting of SHASE   Sep 2019   
Radiative Heat Emitted from High-temperature Equipment Part 6 Simplified Measurement Method of Radiative Heat
Y. Kondo, H. Yoshino, Y. Asawa and S. Yamashita
Annual Meeting of Shase   Sep 2019   
Sealing Efficiency of Double Air Curtain Part 3 CFD Simulation of Double Air Curtain Installed at Refrigerated Room and Store
Y. Tanaka, Y. Takahashi and Y. Kondo
Annual Meeting of SHASE   Sep 2019   
A Study on Improvement System of Thermal Environment and Air Quality in Large Space Workshop Part.3 Temperature Distribution during Heating Operation and Thermal Load Calculation Method
Yusuke ISO, Shigeyuki NAGASAKA, Jiang ZHANG and Yasushi KONDO
Annual Meeting of SHASE   Sep 2019   
Evaluation Method of Complicated Shape Insulation Foam Part 1 Safe Side Estimation of Thermal Resistance with Heated Box Test
O. Suzuki, S. Hagiwara, Y. Nagase and Y. Kondo
Annual Meeting Of AIJ   Sep 2019   
Sealing Efficiency of Double Air Curtain Part 2 CFD Simulation of Store Model and Experimental Study
Y. Takahashi, Y. Tanaka, M. Iida and Y. Kondo
Annual Meeting of AIJ   Sep 2019   
Sealing Efficiency of Double Air Curtain Part 1 CFD Simulation of Double Air Curtain Installed at Refrigerated Room’s Door
Y. Tanaka, Y. Takahashi, M. Iida and Y. Kondo
Annual Meeting of AIJ   Sep 2019   
Radiative Heat Emitted from High-temperature Equipment Part 5 Calculated Results of Simplified Measurement Method of Radiative Heat
H. Yoshino, Y. Kondo, Y. Asawa and S. Yamashita
Annual Meeting of AIJ   Sep 2019   
Radiative Heat Emitted from High-temperature Equipment Part 4 Simplified Measurement Method of Radiative Heat
Y. Kondo, H. Yoshino, Y. Asawa and S. Yamashita
Annual Meeting Of AIJ   Sep 2019   
SURVEY ON OPTICAL AND THERMAL PROPERTY OF LOAD REDUCTION TECHNIQUE INAIR-CONDITIONGIN SYSTEM FOR BUILDING ENVELOPE AND STUDY ON LOAD REDUCTION EFFECT IN AIR-CONDITIONING SYSTEM PART 1 LOAD REDUCTION TECHNIQUE IN AIR-CONDITIONING SYSTEM FOR WINDOWS
Taichi TASAKA, Yasushi KONDO, Kensaku Mabuchi, Shinji HAGIHARA and Tetsuo FUJIMOTO
The 39th Japan Symposium on Thermophysical Properties   Nov 2018   
SURVEY ON OPTICAL AND THERMAL PROPERTY OF LOAD REDUCTION TECHNIQUE IN AIR-CONDITIONING SYSTEM FOR BUILDING ENVELOPE AND STUDY ON LOADREDUCTION EFFECT IN AIR-CONDITIONING SYSTEM PART 2 LOAD REDUCTION TECHNIQUE IN AIR-CONDITIONING SYSTEM
Kensaku MABUCHI, Yasushi KONDO, Taichi TASAKA, Shinji HAGIHARA and Tetsuo FUJIMOTO
The 39th Japan Symposium on Thermophysical Properties   Nov 2018   
Radiative Heat Emitted from High-temperature Equipment Part 3 Shape Factor and Absorption Coefficient Between High-temperature Equipment and Wall Surface
Tomoyuki Kawazoe, Yasushi Kondo, Hajime Yoshino and Yuki Shimanuki
Annual Meeting of AIJ   Sep 2018   
Radiative Heat Emitted from High-temperature Equipment Part 2 Study on Measurement Method of Radiative Heat
Ryuota Mouri, Yasushi Kondo, Hajime Yoshino, Yuki Shimanuki and Tomoyuki Kawazoe
Annual Meeting of AIJ   Sep 2018   
Radiative Heat Emitted from High-temperature Equipment Part 1 Measurement Method of Radiative Heat Adopted by ASHRAE
Yasushi Kondo, Hajime Yoshino, Yuki Shimanuki and Tomoyuki Kawazoe
Annula Meeting of AIJ   Sep 2018   
Influence of Ultraviolet Light on Acrolein Concentration of Exhaust Air and on Oil Layer at Exhaust Duct in Commercial Kitchens
Shinji YAMASHITA, Yasushi KONDO, Hajime YOSHINO, Yasuhisa ASAWA
Annual Meeting of SHASE   Sep 2018   
CFD Simulation on Sealing Efficiency of Double Air Curtain Installed at Refrigerated Room’s Door
Megumi Iida and Yasushi Kondo
Annual Meeting of AIJ   Sep 2018   
Calculation method of ventilation rate to keep appropriate air quality in commercial kitchens
Atsushi OKUDA, Yasushi KONDO, Takashi KURABUCHI, Hajime YOSHINO and Yoshihiro TORIUMI, Toshio YAMANAKA, Hisashi KOTANI
Annual Meeting of SHASE   Sep 2017   
Measurement Method of Radiative Heat Emitted from a High Temperature Heat Source
Tomoyuki KAWAZOE, Yasushi KONDO, Hajime YOSHINO, Atsushi OKUDA and Yuki SHIMANUKI
Annual Meeting of SHASE   Sep 2017   
CFD Simulation on Required Opening Area of an Indoor Parking for Natural Ventilation
Hajime YOSHINO, Yasushi KONDO and Megumi IIDA
Annual Meeting SHASE   Sep 2017   
Characteristic of Energy Use in a Commercial Kitchen
Shinji YAMASHITA, Hajime YOSHINO, Atsushi OKUDA, Yuki SHIMANUKI, Fumihiro MARUYAMA and Yasushi KONDO
Annual Meeting of SHASE   Sep 2017   
Research on Estimation of the Design Cooling Load in the Existing Underground Stations Part 4 Simple Estimation Formula of Air Temperature in Tunnels
Kentaro KIMURA, Katsuhiko SHIBATA, Masafumi SATO and Yasushi KONDO
Annual Meeting of SHASE   Sep 2017   
Improvement of Hot and Humid Condition around Marathon Course by Using Cold Air Flowed out of Subway Ventilation Openings
Megumi Iida and Yasushi Kondo
Annual Meeting of AIJ   Aug 2017   
CFD Simulation on Required Opening Area of an Indoor Parking for Natural Ventilation
Hajime Yoshino and Yasushi Kondo
Annual Meeting of AIJ   Aug 2017   
Measurement of Load Factor of Gas Cooking Appliances in Commercial Kitchens
Yuki Shimanuki, Atsushi Okuda, Humihiro Maruyama, Hajime Yoshino and Yasushi Kondo
Annual Meeting of AIJ   Aug 2017   
High Efficiency Exhaust System for Electrical Flyers in Small Kitchen of Convenience Store
Koichi Taniyama, Kenji Ueyama, Yasushi Kondo and Masayuki Oohira
Annual Meeting of AIJ   Aug 2017   
Measurement Method of Radiative Heat Emitted from a High Temperature Heat Source
Tomoyuki Hawazoe, Yasushi Kondo, Atsushi Okuda and Yuki Shimanuki
Annual Meeting of AIJ   Aug 2017   
Fundamental study on energy use survey and energy saving in a kitchen (part2)
Atsushi Okuda, Yuki Shimanuki, Hajime Yoshino and Yasushi Kondo
Annual Meeting Of AIJ   Aug 2017   
Study on Radiative Heat Generation of Measurement Method from a Heat Source
Tomoyuki Kawazoe, Yasushi Kondo, Hajime Yoshino, Atsushi Okuda and Yuki Shimanuki
The 51st Japanese Joint Conference on Air-Conditiong and Refrigeration   Apr 2017   
CFD Simulation on Reduction of Heat Shock Risk in a Bathroom by Means of Thermal Insulation and Installation of Heater
Yokota Kensuke, Kondo Yasushi et al.
SHASE Annual Meeting   Sep 2016   
Study on Actual Insulation Performance and Design Thermal Conductivity of ALC
Shiode Yuzo, Kondo Yasushi et al.
SHASE Annual Meeting   Sep 2016   
Estimation Method of Hood Capture Efficiency Based on Initial Distribution Ratio
Yasuhiro NAGASAWA et al.
SHASE Annual Meeting   Sep 2016   
Improvement of Indoor Environmental Quality in a Small Kitchen of a Convenience Store with Air Disturbance Caused by a Moving Body Part 2 Experimental Study on Exhaust Hood Shape
Ogura Hisashi et al.
SHASE Annual Meeting   Sep 2016   
Displacement Ventilation System with Ceiling Mounted Diffusers in a Gas Commercial Kitchen Part 1 CFD Simulation on Displacement Ventilation and Conventional Ventilation
KAWAZOE Tomoyuki et al.
SHASE Annual Meeting   Sep 2016   
Displacement Ventilation System with Ceiling Mounted Diffusers in a Gas Commercial Kitchen Part 2 Field Measurement of Thermal Condition and Airflow Visualization
YAMASHITA Shinji et al.
SHASE Annual Meeting   Sep 2016   
Improvement of Indoor Environmental Quality in a Small Kitchen of a Convenience Store with Air Disturbance Caused by a Moving Body Part 1 Comparison between Conventional Ventilation System and Newly Developed Ventilation System by CFD Simulations
Taniyama Koichi et al.
SHASE Annual Meeting   Sep 2016   
Research on Estimation of the Design Cooling Load in the Existing Underground Stations Part 3 Accuracy verification of the load calculation method by block model
KIMURA Kentaro et al.
SHASE Annual Meeting   Sep 2016   
Research on Estimation of the Design Cooling Load in the Existing Underground Stations Part2 Field Measurement of Temperature and Humidity in Tunnels
YAMAGUCHI Keisuke et al.
SHASE Annual Meeting   Sep 2016   
Thermal Environment and Cooling Load in Underground Stations Part 3 Field Measurement of Temperature and Humidity in Tunnels
YAMAGUCHI Keisuke et al.
AIJ Annual Meeting   Aug 2016   
Insulation performance of aged ALC
Shiode Yuzo, Kondo Yasushi et al.
AIJ Annual Meeting   Aug 2016   
Influence of Ultraviolet on Oil Layer on Inner Surface of Exhaust Duct in Commercial Kitchens
KOMIYAMA Hiroki et al.
AIJ Annual Meeting   Aug 2016   
Displacement Ventilation System with Ceiling Mounted Diffusers in a Gas Commercial Kitchen Part 2 Measurement on Thermal and Air Conditions
YAMASHITA Shinji et al.
AIJ Annual Meeting   Aug 2016   
Displacement Ventilation System with Ceiling Mounted Diffusers in a Gas Commercial KitchenPart 1 CFD Simulation on Displacement Ventilation and Conventional Ventilation
KAWAZOE Tomoyuki et al.
AIJ Annual Meeting   Aug 2016   
Thermal Environment and Cooling Load in Underground Stations Part 3 Influence of station structure on train wind
KIMURA Kentaro et al.
AIJ Annual Meeting   Aug 2016   
Study on energy, information and facilities of smart wellness house Part 4 CFD Simulation on Reduction of Heat Shock Riskby Means of Improvement of Thermal Insulation Performance
Yokota Kensuke, Kondo Yasushi et al.
AIJ Annual Meeting   Aug 2016   
Influence of Ultraviolet Light on Oil Mist Concentration within an Exhaust Duct Part 1 Measurement Method of Aerosol/ Gaseous Concentration of Oil and Chemical Substances
Hiroto Komatsu, Yasushi Kondo, Kouki Komiyama, Hajime Yoshino and Atsushi Okuda
AIJ Annual Meeting   Sep 2015   
Experimental Study on The Thermal Insulation Performance of The ALC Panels Part2 Measurement of Thermal Conductivity in Various Conditions
Mizutani Yoshikatsu, Tsuyoshi Seike, Yasushi Kondo, Akio Koyama nad Yuzo Shioide
AIJ Annual Meeting   Sep 2015   
Experimental Study on The Thermal Insulation Performance of The ALC Panels Part1 JIS Standard Value and The Performance Test Value
Shioide Yuzo, Tsuyoshi Seike, Yasushi Kondo, Akio Koyama and Yoshikatsu Mizutani
AIJ Annual Meeting   Sep 2015   
Measurement of space distribution of oil mist generated by commercial cooking equipment Part 2 Measurement results of particle size distribution of oil mist
Yuki Kajiwara, Yasushi Kondo, Yoshihiro Saito, Kouki Komiyama, Atsushi Okuda and Hiroto Komatsu
AIJ Annual Meeting   Sep 2015   
Measurement of space distribution of oil mist generated by commercial cooking equipment Part 1 Measurement method of particle size distribution of oil mist
Saito Yoshihiro, Yasushi Kondo, Yuki Kajiwara, Kouki Komiyama, Atsushi Okuda and Hiroto Komatsu
AIJ Annual Meeting   Sep 2015   
Estimation Method of Hood Capture Efficiency Based on Initial Distribution Ratio Part 2 Adequate Initial Distribution Ratio to Estimate Capture Efficiency
Yasushi Kondo and Hirohito Iwasaki
AIJ Annual Meeting   Sep 2015   

Works

 
Ventilation in Work Spaces
2001
Ventilation Efficiency in Commercial Kitchens
2000
Ventilation in Underground Car Parkings
2000

Research Grants & Projects

 
Indoor Air Quality and Thermal Environment
Airflow and Thermal Environment around Building

Patents

 
特願2014-103733 : Air-conditioning method and system of underground stations
Yasushi Kondo, Kentaro Kimura and Katsuhiko Shibata
特願2009−179109 : Displacement Ventilation System
Yasushi Kondo, Tonets Co., Chubu Electric Power Co. and Horkos Co.
5238758 : Local Ventilation of Smoking Zone
Yasushi Kondo and Ming Kim
5526403 : Displacement Ventilation System
Hajime Yoshino, Shunsuke Ogita, Miwako Fujita, Yasushige Ymamoto and Yasushi Kondo
実用新案 登録第3134263 : Assistant Device of Range Hood
Yoshino Hajime, Ogita Shunsuke, Yamauchi Masao, Fujita Miwako and Kondo Yasushi