F-14 暖房室内の温熱環境評価に関する研究 : (第3報) 床暖房・エアコンにより形成される居室の温熱環境と投入熱量の把握
空気調和・衛生工学会大会 学術講演論文集
- 巻
- 2008
- 号
- 0
- 開始ページ
- 477
- 終了ページ
- 480
- 記述言語
- 日本語
- 掲載種別
- DOI
- 10.18948/shasetaikai.2008.1.0_477
- 出版者・発行元
- 公益社団法人 空気調和・衛生工学会
Heat demands are measured to maintain thermal sensation of various points in a room whose heat loss coefficient is 3.2W/m^2K at a comfort level based on PMV value for each heating equipment of floor heating and air-conditioning system. It was confirmed that heat demand of floor heating system is 16% smaller at a height of 600mm or more than air-conditioning system, and uniformly distributed in the occupied space. Average air velocity and its fluctuation are generally higher in air-conditioning system than floor heating and draft risk is found higher in air-conditioning system.