E-17 ヒートポンプ暖房時と床暖房時における気流性状

空気調和・衛生工学会大会 学術講演論文集
  • 飯野 由香利
  • ,
  • 倉渕 隆
  • ,
  • 岩本 静男
  • ,
  • 遠藤 智行
  • ,
  • 近藤 武士
  • ,
  • 岸田 拓也
  • ,
  • 高橋 誠

2005
0
開始ページ
373
終了ページ
376
記述言語
日本語
掲載種別
DOI
10.18948/shasetaikai.2005.1.0_373
出版者・発行元
公益社団法人 空気調和・衛生工学会

The experiment was conducted in order to clarify airflow characteristics in rooms heated by heat pump and floor heating systems and effects of supply air and cold draft. The following results were obtained: (1) The airflow in rooms heated by a heat pump system circulated gradually and included the high values of power spectrum ratio in the high frequency range. (2) The airflow in rooms heated by floor heating system showed the high values of power spectrum ratio in the low frequency range and low air velocity. (3) The air volume of supply air and shapes of ventilation hole have small effects on airflow characteristics.