論文

査読有り
2017年4月

Improvements of low-detection-limit filter-free fluorescence sensor developed by charge accumulation operation

Japanese Journal of Applied Physics
  • Kiyotsugu Tanaka
  • ,
  • Yong Joon Choi
  • ,
  • Yu Moriwaki
  • ,
  • Takeshi Hizawa
  • ,
  • Tatsuya Iwata
  • ,
  • Fumihiro Dasai
  • ,
  • Yasuyuki Kimura
  • ,
  • Kazuhiro Takahashi
  • ,
  • Kazuaki Sawada

56
4
記述言語
英語
掲載種別
研究論文(国際会議プロシーディングス)
DOI
10.7567/JJAP.56.04CM09
出版者・発行元
IOP PUBLISHING LTD

© 2017 The Japan Society of Applied Physics. We developed a low-detection-limit filter-free fluorescence sensor by a charge accumulation technique. For charge accumulation, a floating diffusion amplifier (FDA), which included a floating diffusion capacitor, a transfer gate, and a source follower circuit, was used. To integrate CMOS circuits with the filter-free fluorescence sensor, we adopted a triple-well process to isolate transistors from the sensor on a single chip. We detected 0.1nW fluorescence under the illumination of excitation light by 1.5 ms accumulation, which was one order of magnitude greater than that of a previous current detection sensor.