MISC

2011年3月

Accuracy in Permeability Measurement by a Combined Microstrip Line-Coaxial Conductor Method

IEICE TRANSACTIONS ON ELECTRONICS
  • Keigo Kanemaru
  • ,
  • Atsushi Kuramoto
  • ,
  • Tomohiko Kanie
  • ,
  • Yuichi Noro
  • ,
  • Takashi Takeo

E94C
3
開始ページ
327
終了ページ
333
記述言語
英語
掲載種別
DOI
10.1587/transele.E94.C.327
出版者・発行元
IEICE-INST ELECTRONICS INFORMATION COMMUNICATIONS ENG

In this paper, accuracy or error in permeability measurement using a combined microstrip line-coaxial conductor method was investigated. The measurement circuit used in this study is composed of a microstrip line (MSL) circuit and a grounded metal pipe with a center conductor passing through it coaxially. A sample is placed between the metal pipe and the center conductor. We evaluated the measurement accuracy for this measurement arrangement with electromagnetic simulation for the case where there are gaps between the sample and the holder. As a result, it has been shown that the normalized errors for this method have similar gap size dependence to the conventional coaxial method, but are about 10 to 20 percent greater than the coaxial method With a view to improving the measurement accuracy, a correction method for the error is also discussed.

リンク情報
DOI
https://doi.org/10.1587/transele.E94.C.327
J-GLOBAL
https://jglobal.jst.go.jp/detail?JGLOBAL_ID=201102254174354024
Web of Science
https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=JSTA_CEL&SrcApp=J_Gate_JST&DestLinkType=FullRecord&KeyUT=WOS:000290126400013&DestApp=WOS_CPL
ID情報
  • DOI : 10.1587/transele.E94.C.327
  • ISSN : 0916-8524
  • eISSN : 1745-1353
  • J-Global ID : 201102254174354024
  • Web of Science ID : WOS:000290126400013

エクスポート
BibTeX RIS