論文

2017年12月

Retinal Nerve Fiber Layer Defect and Paracentral Scotoma after Internal Limiting Membrane Peeling with a Nitinol Loop.

Acta medica Okayama
  • Ryo Matoba
  • ,
  • Yuki Morizane
  • ,
  • Shuhei Kimura
  • ,
  • Shinji Toshima
  • ,
  • Fumio Shiraga

71
6
開始ページ
539
終了ページ
542
記述言語
英語
掲載種別
DOI
10.18926/AMO/55592

Internal limiting membrane (ILM) peeling is an important maneuver in vitrectomy for macular holes (MHs). A nitinol loop is a surgical instrument designed to create an edge on the ILM and peel the ILM safely and consistently. The effect of using a nitinol loop for ILM peeling on the retina is not clear. We report here on a case of an idiopathic full-thickness MH in an adult woman, in whom retinal damage was revealed after her ILM was peeled using a nitinol loop.

リンク情報
DOI
https://doi.org/10.18926/AMO/55592
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/29276228
ID情報
  • DOI : 10.18926/AMO/55592
  • PubMed ID : 29276228

エクスポート
BibTeX RIS