1995年4月
FORCED-CONVECTION FREEZING HEAT-TRANSFER CHARACTERISTICS IN A RETURN BEND WITH A RECTANGULAR CROSS-SECTION
HEAT AND MASS TRANSFER
- ,
- ,
- ,
- 巻
- 30
- 号
- 4
- 開始ページ
- 205
- 終了ページ
- 214
- 記述言語
- 英語
- 掲載種別
- 研究論文(学術雑誌)
- DOI
- 10.1007/BF01602764
- 出版者・発行元
- SPRINGER VERLAG
Experiments have been performed to investigate the freezing heat transfer characteristics in a return bend with a rectangular cross section. The experiments were carried out for two kinds of duct heights of 30 and 50 mm under the fixed size of 300 mm in duct width and 159 mm in curvature radius of convex wall. Both the convex and concave walls of a return bend were kept less than the freezing temperature of water. It was found that the freezing characteristics on the convex wall are markedly different from those on the concave wall of a return bend, and that the cooling temperature ratio is one of the most important parameters on the forced-convection freezing heat transfer in a return bend.
- リンク情報
- ID情報
-
- DOI : 10.1007/BF01602764
- ISSN : 0042-9929
- Web of Science ID : WOS:A1995RB77300001