2003年6月
Three-dimensional CT angiography of the hepatic artery: Use of multi-detector row helical CT and a contrast agent
RADIOLOGY
- ,
- ,
- ,
- ,
- ,
- ,
- ,
- 巻
- 227
- 号
- 3
- 開始ページ
- 883
- 終了ページ
- 889
- 記述言語
- 英語
- 掲載種別
- DOI
- 10.1148/radiol.2273011964
- 出版者・発行元
- RADIOLOGICAL SOC NORTH AMERICA
The administration of a contrast agent to obtain optimal images at three-dimensional computed tomographic (CT) angiography of the hepatic artery by using multi-detector row helical CT was investigated. Three-dimensional CT angiographic images were evaluated visually, and quantitative evaluation was performed by measuring the postcontrast CT number of the aorta. The injection rate of 5 mL/sec was significantly superior to that of 4 mL/sec in both evaluations. At administration of a contrast agent with 300 or 350 milligrams of iodine per milliliter, there were no significant differences in either evaluations. The preferable injection rate to obtain sufficient three-dimensional CT angiographic data was 5 mL/sec. (C) RSNA, 2003.
- リンク情報
- ID情報
-
- DOI : 10.1148/radiol.2273011964
- ISSN : 0033-8419
- Web of Science ID : WOS:000182924800040