論文

査読有り 国際誌
2018年8月31日

A loop-mediated isothermal amplification assay for the detection and quantification of JC polyomavirus in cerebrospinal fluid: a diagnostic and clinical management tool and technique for progressive multifocal leukoencephalopathy.

Virology journal
  • Hitomi Kinoshita
  • ,
  • Kazuo Nakamichi
  • ,
  • Chang-Kweng Lim
  • ,
  • Mutsuyo Takayama-Ito
  • ,
  • Lixin Wang
  • ,
  • Itoe Iizuka
  • ,
  • Ichiro Kurane
  • ,
  • Masayuki Saijo

15
1
開始ページ
136
終了ページ
136
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1186/s12985-018-1046-z

BACKGROUND: JC polyomavirus (JCV) is the causative agent of progressive multifocal leukoencephalopathy (PML), a demyelinating disease of the central nervous system in immunosuppressed patients. PML usually has a poor prognosis. Detection and quantification of the JCV genome in cerebrospinal fluid (CSF) is an efficacious tool for the diagnosis and management of PML, for which proper therapeutic interventions are required. METHODS: A loop-mediated isothermal amplification (LAMP) assay was applied for the quantitative detection of JCV. The LAMP assay was evaluated for the efficacy in diagnosis of PML in comparison with the TaqMan-based quantitative real-time PCR (qPCR) assay using 153 CSF specimens collected from patients with suspected PML. RESULTS: The LAMP assay showed no cross-reactivity against other polyomavirus plasmids, viral DNA, and viral RNA, which causes encephalitis, and detected 1 copy of the standard DNA per reaction. Among 50 qPCR-positives, 42 specimens (containing JCV genome ranged from 3.2 × 100 to 3.2 × 106 copies/reaction) showed positive reactions and 8 specimens (containing 0.9 to 19.9 copies/reaction) showed negative in the LAMP assay. Furthermore, 3 of 103 qPCR-negative specimens showed positive reactions in the LAMP assay. The sensitivity, specificity, positive predictive value, and negative predictive values of the LAMP assay were 84% (42/50), 97% (100/103), 93% (42/45), and 93% (100/108), respectively. The kappa statistic was 0.83. The JCV loads determined by the LAMP assay showed a strong positive correlation with those determined by the qPCR assay for 33 specimens with copy numbers of ≥1 copies/reaction (r = 0.89). Additionally, the LAMP assay could monitor the JCV genome copy number in CSF for sequential samples equivalently to qPCR assay. CONCLUSIONS: The newly developed LAMP assay is highly specific against JCV and detect the JCV genome in the sample DNA containing 20 or more copies of JCV genome per reaction with 100% sensitivity (n = 29), which corresponds to ≥3 × 103 copies/mL of CSF. The LAMP assay is useful for the diagnosis and offers valuable information for the evaluation and management of PML in the clinical setting.

リンク情報
DOI
https://doi.org/10.1186/s12985-018-1046-z
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/30170628
PubMed Central
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119251
ID情報
  • DOI : 10.1186/s12985-018-1046-z
  • PubMed ID : 30170628
  • PubMed Central 記事ID : PMC6119251

エクスポート
BibTeX RIS