論文

国際誌
2021年7月15日

Arterial Transit Time-Based Multidelay Combination Strategy Improves Arterial Spin Labeling Cerebral Blood Flow Measurement Accuracy in Severe Steno-Occlusive Diseases.

Journal of magnetic resonance imaging : JMRI
  • Shiori Amemiya
  • ,
  • Yusuke Watanabe
  • ,
  • Naoyuki Takei
  • ,
  • Tsuyoshi Ueyama
  • ,
  • Satoru Miyawaki
  • ,
  • Satoshi Koizumi
  • ,
  • Seiji Kato
  • ,
  • Hidemasa Takao
  • ,
  • Osamu Abe
  • ,
  • Nobuhito Saito

55
1
開始ページ
178
終了ページ
187
記述言語
英語
掲載種別
研究論文(学術雑誌)
DOI
10.1002/jmri.27823

BACKGROUND: Although perfusion imaging plays a key role in the management of steno-occlusive diseases, the clinical usefulness of arterial spin labeling (ASL) is limited by technical issues. PURPOSE: To examine the effect of arterial transit time (ATT) prolongation on cerebral blood flow (CBF) measurement accuracy and identify the best CBF measurement protocol for steno-occlusive diseases. STUDY TYPE: Prospective. POPULATION: Moyamoya (n = 10) and atherosclerotic diseases (n = 8). FIELD STRENGTH/SEQUENCE: A 3.0T/3DT1 -weighted and ASL. ASSESSMENT: Hadamard-encoded multidelay ASL scans with/without vessel suppression (VS) and single-delay ASL scans with long-label duration (LD) and long postlabeling delay (PLD), referred to as long-label long-delay (LLLD), were acquired. CBF measurement accuracy and its ATT dependency, measured as the correlation between the relative CBF measurement difference (ASL-single-photon emission computed tomography [SPECT]) and ATT, were compared among 1) Combo (incorporating multidelay and LLLD data based on ATT), 2) standard (LD/PLD = 1333/2333 msec), and 3) LLLD (LD/PLD = 4000/4000 msec) protocols, using whole-brain voxel-wise correlation with reference standard SPECT CBF. The effect of VS on CBF measurement accuracy was also assessed. STATISTICAL TESTS: Pearson's correlation coefficient, repeated-measures analysis of variance, t-test. P< 0.05 was considered significant. RESULTS: Pearson's correlation coefficients between ASL and SPECT CBF measurements were as follows: Combo = 0.55 ± 0.09; standard = 0.52 ± 0.12; LLLD = 0.41 ± 0.10. CBF measurement was least accurate in LLLD and most accurate in Combo. VS significantly improved overall CBF measurement accuracy in the standard protocol and in moyamoya patients for the Combo. ATT dependency analysis revealed that, compared with Combo, the standard and LLLD protocols showed significantly lower and negative and significantly higher and positive correlations, respectively (standard = -0.12 ± 0.04, Combo = -0.04 ± 0.03, LLLD = 0.17 ± 0.03). DATA CONCLUSION: By using ATT-corrected CBF derived from LD/PLD = 1333/2333 msec as a base and by compensating underestimation in delayed regions using multidelay scans, the ATT-based Combo strategy improves CBF measurement accuracy compared with single-delay protocols in severe steno-occlusive diseases. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

リンク情報
DOI
https://doi.org/10.1002/jmri.27823
PubMed
https://www.ncbi.nlm.nih.gov/pubmed/34263988
ID情報
  • DOI : 10.1002/jmri.27823
  • PubMed ID : 34263988

エクスポート
BibTeX RIS